Welcome to LookChem.com Sign In|Join Free

CAS

  • or

34350-99-7

Post Buying Request

34350-99-7 Suppliers

Recommended suppliersmore

  • Product
  • FOB Price
  • Min.Order
  • Supply Ability
  • Supplier
  • Contact Supplier

34350-99-7 Usage

Check Digit Verification of cas no

The CAS Registry Mumber 34350-99-7 includes 8 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 5 digits, 3,4,3,5 and 0 respectively; the second part has 2 digits, 9 and 9 respectively.
Calculate Digit Verification of CAS Registry Number 34350-99:
(7*3)+(6*4)+(5*3)+(4*5)+(3*0)+(2*9)+(1*9)=107
107 % 10 = 7
So 34350-99-7 is a valid CAS Registry Number.

34350-99-7Downstream Products

34350-99-7Relevant articles and documents

Evaluation of monolithic C18 HPLC columns for the fast analysis of pilocarpine hydrochloride in the presence of its degradation products

El Deeb,Schepers,Waetzig

, p. 751 - 756 (2007/10/03)

Monolithic Performance C18 HPLC columns (Chromolith Performance RP-18e, Merck) were applied for the determination of pilocarpine hydrochloride in the presence of its degradation products isopilocarpine, pilocarpic acid and isopilocarpic acid. The method was validated using a set of six monolithic columns and compared to a conventional C18 column. The separation of pilocarpine from its degradation products was investigated on monolithic columns at different flow rates from 1 to 9 ml/min. Superior resolution was obtained using monolithic columns over the conventional C18 column at the same flow rate of 1 ml/min with a total run time of 9 min compared to 13.5 min for the conventional C18 column. Comparable resolution to that obtained in the C18 column (but with better peak symmetry) was obtained at a flow rate of 4 ml/min, although the total run time was reduced to 3.5 min. The precision for both retention time and peak area was investigated over a wide concentration range and found to be equal, or slightly better on Chromolith Performance compared to the conventional column. The overall RSDs% ranged from 0.5% to 1.16% for the conventional column, while for monolithic columns ranged from 0.38% to 0.87% at a flow rate of 1 ml/min and from 0.38% to 0.89% at a flow rate of 4 ml/min. Monolithic column to column reproducibility (n = 6) was measured. The RSDs% ranged from 0.34% to 0.68% for retention time and from 0.3% to 0.94% for peak areas. The detection and quantitation limits on monolithic columns at both flow rates (1 and 4 ml/min) were found to be 0.17 μg/ml and 0.5 μg/ml, compared to 0.31 μg/ml and 1 μg/ml on the conventional column. Monolithic silica rods have also shown the advantage of reducing the time to wash and to re-equilibrate the column. The method showed good linearity and recovery and was found to be suitable for the analysis of pilocarpine hydrochloride formulations.

On the stability of pilocarpine hydrochloride in eye drops

Porst,Kny

, p. 23 - 29 (2007/10/02)

-

Quantitative determination of pilocarpine, isopilocarpine, pilocarpic acid, and isopilocarpic acid in clinical ophthalmic pilocarpine formulations by reversed-phase liquid chromatography

Noordam,Maat,Beyerman

, p. 96 - 97 (2007/10/02)

-

Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1

What can I do for you?
Get Best Price

Get Best Price for 34350-99-7