    1. Product Name: 2',3,4,4',5-PENTACHLOROBIPHENYL
    2. Synonyms: PCB-123;PCB NO 123;BZ NO 123;2',3,4,4',5-PENTACHLOROBIPHENYL;23445PECB;23445PENTACHLOROBIPHENYL(2,3',4,4',5'-PENTACHLOROISOMER);CB-123;2',3,4,4',5-Pentachlorobiphenyl 5mg [65510-44-3]
    3. CAS NO:65510-44-3
    4. Molecular Formula: C12H5Cl5
    5. Molecular Weight: 326.43
    6. EINECS: N/A
    7. Product Categories: N/A
    8. Mol File: 65510-44-3.mol
    9. Article Data: 3
  • Chemical Properties

    1. Melting Point: N/A
    2. Boiling Point: 390.2 °C at 760 mmHg
    3. Flash Point: 192.1 °C
    4. Appearance: /
    5. Density: 1.522 g/cm3
    6. Refractive Index: N/A
    7. Storage Temp.: room temp
    8. Solubility: Chloroform (Slightly), Methanol (Slightly, Heated, Sonicated)
    9. CAS DataBase Reference: 2',3,4,4',5-PENTACHLOROBIPHENYL(CAS DataBase Reference)
    10. NIST Chemistry Reference: 2',3,4,4',5-PENTACHLOROBIPHENYL(65510-44-3)
    11. EPA Substance Registry System: 2',3,4,4',5-PENTACHLOROBIPHENYL(65510-44-3)
  • Safety Data

    1. Hazard Codes: N
    2. Statements: 33-50/53
    3. Safety Statements: 60-61
    4. WGK Germany:
    5. RTECS:
    6. HazardClass: N/A
    7. PackingGroup: N/A
    8. Hazardous Substances Data: 65510-44-3(Hazardous Substances Data)

65510-44-3 Usage

Uses

2'',3,4,4'',5-Pentachlorobiphenyl is a polychlorinated biphenyl (PCB) congeners.

Check Digit Verification of cas no

The CAS Registry Mumber 65510-44-3 includes 8 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 5 digits, 6,5,5,1 and 0 respectively; the second part has 2 digits, 4 and 4 respectively.
Calculate Digit Verification of CAS Registry Number 65510-44:
(7*6)+(6*5)+(5*5)+(4*1)+(3*0)+(2*4)+(1*4)=113
113 % 10 = 3
So 65510-44-3 is a valid CAS Registry Number.

65510-44-3SDS

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 13, 2017

Revision Date: Aug 13, 2017

1.Identification

1.1 GHS Product identifier

Product name 2',3,4,4',5-Pentachlorobiphenyl

1.2 Other means of identification

Product number -
Other names 1,2,3-trichloro-5-(2,4-dichlorophenyl)benzene

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only.
Uses advised against no data available

1.4 Supplier's details

1.5 Emergency phone number

Emergency phone number -
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

More Details:65510-44-3 SDS

65510-44-3Downstream Products

65510-44-3Relevant articles and documents

Emission factors and importance of PCDD/Fs, PCBs, PCNs, PAHs and PM 10 from the domestic burning of coal and wood in the U.K.

Lee, Robert G. M.,Coleman, Peter,Jones, Joanne L.,Jones, Kevin C.,Lohmann, Rainer

, p. 1436 - 1447 (2007/10/03)

This paper presents emission factors (EFs) derived for a range of persistent organic pollutants (POPs) when coal and wood were subject to controlled burning experiments, designed to simulate domestic burning for space heating. A wide range of POPs were emitted, with emissions from coal being higher than those from wood. Highest EFs were obtained for particulate matter, PM10, (~ 10 g/kg fuel) and polycyclic aromatic hydrocarbons (~ 100 mg/ kg fuel for ΣPAHs). For chlorinated compounds, EFs were highest for polychlorinated biphenyls (PCBs), with polychlorinated naphthalenes (PCNs), dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) being less abundant. EFs were on the order of 1000 ng/kg fuel for ΣPCBs, 100s ng/ kg fuel for ΣPCNs and 100 ng/kg fuel for ΣPCDD/Fs. The study confirmed that mono- to trichlorinated dibenzofurans, Cl1,2,3DFs, were strong indicators of low temperature combustion processes, such as the domestic burning of coal and wood. It is concluded that numerous PCB and PCN congeners are routinely formed during the combustion of solid fuels. However, their combined emissions from the domestic burning of coal and wood would contribute only a few percent to annual U.K. emission estimates. Emissions of PAHs and PM 10 were major contributors to U.K. national emission inventories. Major emissions were found from the domestic burning for Cl1,2,3DFs, while the contribution of PCDD/F-ΣTEQ to total U.K. emissions was minor.

Physical, spectral and chromatographic properties of all 209 individual PCB congeners

Bolgar,et al.

, p. 2687 - 2705 (2007/10/03)

Through the use of two capillary GC columns: 40% octadecyl/ 15% phenyl methyl siloxane and 50% phenyl methyl siloxane, it was possible to separate 201 PCB congeners with only four unresolved pairs. The data compiled in this study for all 209 congeners will aid in the identification of selected individual components of these environmental pollutants. The use of this data also presents the opportunity for the improved quantification of the commercial PCB formulations. -from Authors

Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1

What can I do for you?
Get Best Price

Get Best Price for 65510-44-3