Welcome to LookChem.com Sign In|Join Free
  • or
Z-L-Arg-L-Arg is a chemical with a specific purpose. Lookchem provides you with multiple data and supplier information of this chemical.

126712-73-0

Post Buying Request

126712-73-0 Suppliers

Recommended suppliers

  • Product
  • FOB Price
  • Min.Order
  • Supply Ability
  • Supplier
  • Contact Supplier

126712-73-0 Usage

Check Digit Verification of cas no

The CAS Registry Mumber 126712-73-0 includes 9 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 6 digits, 1,2,6,7,1 and 2 respectively; the second part has 2 digits, 7 and 3 respectively.
Calculate Digit Verification of CAS Registry Number 126712-73:
(8*1)+(7*2)+(6*6)+(5*7)+(4*1)+(3*2)+(2*7)+(1*3)=120
120 % 10 = 0
So 126712-73-0 is a valid CAS Registry Number.

126712-73-0Downstream Products

126712-73-0Relevant academic research and scientific papers

Label free screening of enzyme inhibitors at femtomole scale using segmented flow electrospray ionization mass spectrometry

Sun, Shuwen,Slaney, Thomas R.,Kennedy, Robert T.

experimental part, p. 5794 - 5800 (2012/08/14)

Droplet-based microfluidics is an attractive platform for screening and optimizing chemical reactions. Using this approach, it is possible to reliably manipulate nanoliter volume samples and perform operations such as reagent addition with high precision, automation, and throughput. Most studies using droplet microfluidics have relied on optical techniques to detect the reaction; however, this requires engineering color or fluorescence change into the reaction being studied. In this work, we couple electrospray ionization mass spectrometry (ESI-MS) to nanoliter scale segmented flow reactions to enable direct (label-free) analysis of reaction products. The system is applied to a screen of inhibitors for cathepsin B. In this approach, solutions of test compounds (including three known inhibitors) are arranged as an array of nanoliter droplets in a tube segmented by perfluorodecalin. The samples are pumped through a series of tees to add enzyme, substrate (peptides), and quenchant. The resulting reaction mixtures are then infused into a metal-coated, fused silica ESI emitter for MS analysis. The system has potential for high-throughput as reagent addition steps are performed at 0.7 s per sample and ESI-MS at up to 1.2 s per sample. Carryover is inconsequential in the ESI emitter and between 2 and 9% per reagent addition depending on the tee utilized. The assay was reliable with a Z-factor of ~0.8. The method required 0.8 pmol of test compound, 1.6 pmol of substrate, and 5 fmol of enzyme per reaction. Segmented flow ESI-MS allows direct, label free screening of reactions at good throughput and ultralow sample consumption.

Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1 Customer Service

What can I do for you?
Get Best Price

Get Best Price for 126712-73-0