Welcome to LookChem.com Sign In|Join Free
  • or
C68H79BF2IN5O2 is a chemical with a specific purpose. Lookchem provides you with multiple data and supplier information of this chemical.

1353054-63-3

Post Buying Request

1353054-63-3 Suppliers

Recommended suppliers

  • Product
  • FOB Price
  • Min.Order
  • Supply Ability
  • Supplier
  • Contact Supplier

1353054-63-3 Usage

Check Digit Verification of cas no

The CAS Registry Mumber 1353054-63-3 includes 10 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 7 digits, 1,3,5,3,0,5 and 4 respectively; the second part has 2 digits, 6 and 3 respectively.
Calculate Digit Verification of CAS Registry Number 1353054-63:
(9*1)+(8*3)+(7*5)+(6*3)+(5*0)+(4*5)+(3*4)+(2*6)+(1*3)=133
133 % 10 = 3
So 1353054-63-3 is a valid CAS Registry Number.

1353054-63-3Downstream Products

1353054-63-3Relevant academic research and scientific papers

Oligo(p-phenylene ethynylene)-BODIPY derivatives: Synthesis, energy transfer, and quantum-chemical calculations

Yin, Shouchun,Leen, Volker,Jackers, Carine,Beljonne, David,Van Averbeke, Bernard,Van Der Auweraer, Mark,Boens, Noel,Dehaen, Wim

experimental part, p. 13247 - 13257 (2012/02/06)

The synthesis and energy-transfer properties of a series of oligo(p-phenylene ethynylene)-BODIPY (OPEB) cassettes are reported. A series of oligo(p-phenylene ethynylene)s (OPEs) with different conjugated chain lengths as energy donor subunit in the energy-transfer system were capped at both ends with BODIPY chromophores as energy-acceptor subunits. The effect of the conjugated chain of OPEs on energy transfer in the OPEB cassettes was investigated by UV/Vis and fluorescence spectroscopy and modeling. With increasing number n of phenyl acetylene units (n=1-7), the absorption and emission maxima of OPEn are bathochromically shifted. In the OPEBn analogues, the absorption maximum assigned to the BODIPY moieties is independent of the length of the OPE spacer. However, the relative absorption intensity of the BODIPY band decreases when the number of phenyl acetylene units is increased. The emission spectra of OPEBn are dominated by a band peaking at 613 nm, corresponding to emission of the BODIPY moieties, regardless of whether excitation is at 420 or 550 nm. Furthermore, a very small band is observed with a maximum between 450 and 500 nm, and its intensity relative to that of the BODIPY emission increases with increasing n, that is, the excited state of OPE subunits is efficiently quenched in OPEBn by energy transfer to the BODIPY moieties. Energy transfer (ET) from OPEn to BODIPY in OPEBn is very efficient (all φET values are greater than 98 %) and only slightly decreases with increasing length of the OPE units. These results are supported by theoretical studies that show very high energy transfer efficiency (φET>75 %) from the OPE spacer to the BODIPY end-groups for chains with up to 15-20 units.

Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1 Customer Service

What can I do for you?
Get Best Price

Get Best Price for 1353054-63-3