Welcome to LookChem.com Sign In|Join Free

CAS

  • or

1367372-23-3

Post Buying Request

1367372-23-3 Suppliers

Recommended suppliersmore

  • Product
  • FOB Price
  • Min.Order
  • Supply Ability
  • Supplier
  • Contact Supplier

1367372-23-3 Usage

Check Digit Verification of cas no

The CAS Registry Mumber 1367372-23-3 includes 10 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 7 digits, 1,3,6,7,3,7 and 2 respectively; the second part has 2 digits, 2 and 3 respectively.
Calculate Digit Verification of CAS Registry Number 1367372-23:
(9*1)+(8*3)+(7*6)+(6*7)+(5*3)+(4*7)+(3*2)+(2*2)+(1*3)=173
173 % 10 = 3
So 1367372-23-3 is a valid CAS Registry Number.

1367372-23-3Downstream Products

1367372-23-3Relevant articles and documents

Improvement of estradiol esters monitoring in bovine hair by dansylation and liquid chromatography/tandem mass spectrometry analysis in multiple reaction monitoring and precursor ion scan modes

Bichon,Béasse,Prevost,Christien,Courant,Monteau,Le Bizec

, p. 819 - 827 (2012)

Rationale: The control of forbidden anabolic practices in cattle in the European Union has become challenging since endogenous compounds such as estradiol derivatives can potentially be used as growth promoters. Due to the great difficulty in establishing a reference threshold value for endogenous steroids, the direct detection of steroid esters in hair is an efficient strategy for the detection of 'natural' steroid abuse in cattle. Methods: The present study aimed to develop and validate according to the current European standards a specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) analytical strategy to monitor estrogen esters in bovine hair. The analysis was performed by positive ion electrospray ionisation (ESI+) after dansylation. Two acquisition modes were then assessed: single reaction monitoring and precursor ion scanning. Results: The results showed that the introduction of a dansylation step strongly improves the sensitivity of the detection of estradiol-17-esters by LC/(ESI+)-MS/MS. The CCα values are in the range 1-10 ng g-1 after optimisation, except for estradiol decanoate for which the derivatisation is not efficient. In addition, this LC/MS/MS approach makes it possible to carry out a precursor ion scan to screen for the presence of these estradiol 17-esters in hair samples. Conclusions: Based on the specific product ions, i.e. m/z 255 in native conditions or m/z 171 after dansylation, this strategy has the advantage of detecting any (un)known estradiol ester and of giving access to the [M + H]+ ion of the suspected ester through only a single analysis.

Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1

What can I do for you?
Get Best Price

Get Best Price for 1367372-23-3