Welcome to LookChem.com Sign In|Join Free
  • or
1,2,3,4,5-Pentachlorobibenzene is a chemical with a specific purpose. Lookchem provides you with multiple data and supplier information of this chemical.

25429-29-2

Post Buying Request

25429-29-2 Suppliers

Recommended suppliers

  • Product
  • FOB Price
  • Min.Order
  • Supply Ability
  • Supplier
  • Contact Supplier

25429-29-2 Usage

Safety Profile

Moderately toxic by unspecified route. When heated to decomposition it emits toxic fumes of Clí.

Check Digit Verification of cas no

The CAS Registry Mumber 25429-29-2 includes 8 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 5 digits, 2,5,4,2 and 9 respectively; the second part has 2 digits, 2 and 9 respectively.
Calculate Digit Verification of CAS Registry Number 25429-29:
(7*2)+(6*5)+(5*4)+(4*2)+(3*9)+(2*2)+(1*9)=112
112 % 10 = 2
So 25429-29-2 is a valid CAS Registry Number.
InChI:InChI=1/C12H5Cl5/c13-8-7(6-4-2-1-3-5-6)9(14)11(16)12(17)10(8)15/h1-5H

25429-29-2SDS

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 14, 2017

Revision Date: Aug 14, 2017

1.Identification

1.1 GHS Product identifier

Product name 1,2,3,5,6-pentachloro-5-phenylcyclohexa-1,3-diene

1.2 Other means of identification

Product number -
Other names Biphenyl,pentachloro-(6CI,7CI,8CI)

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only.
Uses advised against no data available

1.4 Supplier's details

1.5 Emergency phone number

Emergency phone number -
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

More Details:25429-29-2 SDS

25429-29-2Upstream product

25429-29-2Downstream Products

25429-29-2Relevant academic research and scientific papers

Effects of oxygen on formation of PCB and PCDD/F on extracted fly ash in the presence of carbon and cupric salt

Pekarek,Grabic,Marklund,Puncochar,Ullrich

, p. 777 - 782 (2007/10/03)

The effect of oxygen-nitrogen atmosphere (N2 + 10%O2, N2 + 1%O2 and 99.999% N2) on the formation of PCB, PCDD and PCDF by the de novo synthetic reactions in the system consisting of extracted fly ash

Removal of dioxins and related aromatic hydrocarbons from flue gas streams by adsorption and catalytic destruction

Liljelind, Per,Unsworth, John,Maaskant, Onno,Marklund, Stellan

, p. 615 - 623 (2007/10/03)

The dioxin removing capacity of the shell dedioxin system (SDDS a - Ti/V oxidative type catalyst) has been tested using the Umefa lab-scale incinerator over the temperature range 100 -230°C and at space velocities of 8000 and 40,000 h-1. Other analogous organic compounds, such as PCBs, PAHs, chlorobenzenes and chlorophenols have also been investigated. Results show a high degree of dioxin removal already at 100°C (82%), which occurs mainly by adsorption. When the temperature is raised a transition towards destruction is seen and at 150°C, gas hour space velocity (GHSV) 8000 and at 230°C, GHSV 40,000 virtually all removal is by destruction. High PCDD/F destruction efficiencies are reported (> 99.9%, based on I-TEQ); the other dioxin-related species and PAHs are also removed and destroyed to a significant extent. The SDDS has proved to be an effective means of destroying organic compounds in the gas phase, particularly dioxins, at temperatures as low as 150°C.

Influence of combustion conditions on the PCDD/F-, PCB-, PCBz- and PAH- concentrations in the post-combustion chamber of a waste incineration pilot plant

Blumenstock,Zimmermann,Schramm,Kettrup

, p. 987 - 993 (2007/10/03)

Experiments at a pilot scale waste incinerator (0.5 MW thermal power) showed that the conditions in the postcombustion chamber (650-900°C) are strongly influencing the formation of chlorinated and non-chlorinated aromatics. Non-optimal combustion conditions resulted in increased concentrations of mono- to trichlorinated dibenzo-p-dioxins (PCDD), dibenzofurans (PCDF) and polycyclic aromatic hydrocarbons (PAH), while chlorinated benzenes (PCBz), polychlorinated biphenyls (PCB) and the higher chlorinated PCDD/F are only weakly affected or even decrease. The changes in concentration of the compounds investigated over a time span of hours gave hints on 'memory effects' in this combustion zone. For mono- and dichlorinated benzenes, a high correlation (r2 = 0.80) with the international toxicity equivalent (I-TEQ) value of PCDD/F was observed. As recently has been demonstrated, this correlation can be utilized for an indirect on-line measurement of the I-TEQ by a novel laser mass spectrometric technique (REMPI-TOFMS). (C) 2000 Elsevier Science Ltd.

Influence of variation in combustion conditions on the primary formation of chlorinated organic micropollutants during municipal solid waste combustion

Wikstroem,Tysklind,Marklund

, p. 4263 - 4269 (2007/10/03)

The aim of this study was to investigate the influence of variation in combustion conditions on the primary formation of organic micropollutants (OMPs). The flue gas samples were taken at a relatively high flue gas temperature (650°C), to enable mechanistic studies on the high temperature formation (primary formation). Eleven experiments were performed in a laboratory scale fluidized bed reactor fed with an artificial municipal solid waste (MSW). The samples were analyzed for mono- to octachlorinated dibenzo- p-dioxins and dibenzofurans (CDDs/Fs), tri- to decachlorinated biphenyls (CBs), di- to hexachlorinated benzenes (CBzs), and di- to pentachlorinated phenols (CPhs). In addition to chlorinated OMPs, nonchlorinated dibenzo-p- dioxin (DD), dibenzofuran (DF), and biphenyl (BP) were analyzed. The experiments show that variations in the CE influence the degree of chlorination of the organic micropollutants. A correlation between low CE and formation of non- and low-chlorinated DMPs was seen and a distinct relationship of higher chlorinated homologues and efficient combustion condition. Thus, the DiCDFs and DiCBzs are formed during low combustion efficiency (CE), while the PeCDF and PeCBzs formation take place at higher CE. The distribution between primary and secondary air is important for the formation of higher CDD/Fs and CBzs. The primary formation of CDDs and CDFs is through different mechanisms. The CDDs are mainly formed by condensation of CPhs, while the CDFs are formed through a non- or a low-chlorinated precursor followed by further chlorination reactions.

Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1 Customer Service

What can I do for you?
Get Best Price

Get Best Price for 25429-29-2