Welcome to LookChem.com Sign In|Join Free
  • or
2-Propanol, 1-[(1,1-dimethylethyl)amino]-3-[(2-methyl-1H-indol-4-yl)oxy]-, benzoate (ester), (S)- is a chemical with a specific purpose. Lookchem provides you with multiple data and supplier information of this chemical.

62697-41-0

Post Buying Request

62697-41-0 Suppliers

Recommended suppliers

  • Product
  • FOB Price
  • Min.Order
  • Supply Ability
  • Supplier
  • Contact Supplier

62697-41-0 Usage

Check Digit Verification of cas no

The CAS Registry Mumber 62697-41-0 includes 8 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 5 digits, 6,2,6,9 and 7 respectively; the second part has 2 digits, 4 and 1 respectively.
Calculate Digit Verification of CAS Registry Number 62697-41:
(7*6)+(6*2)+(5*6)+(4*9)+(3*7)+(2*4)+(1*1)=150
150 % 10 = 0
So 62697-41-0 is a valid CAS Registry Number.

62697-41-0SDS

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 18, 2017

Revision Date: Aug 18, 2017

1.Identification

1.1 GHS Product identifier

Product name (S)-bopindolol

1.2 Other means of identification

Product number -
Other names -

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only.
Uses advised against no data available

1.4 Supplier's details

1.5 Emergency phone number

Emergency phone number -
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

More Details:62697-41-0 SDS

62697-41-0Upstream product

62697-41-0Downstream Products

62697-41-0Relevant academic research and scientific papers

Enantioselective potential of polysaccharide-based chiral stationary phases in supercritical fluid chromatography

Kucerova, Gabriela,Kalikova, Kveta,Tesarova, Eva

supporting information, p. 239 - 246 (2017/05/29)

The enantioselective potential of two polysaccharide-based chiral stationary phases for analysis of chiral structurally diverse biologically active compounds was evaluated in supercritical fluid chromatography using a set of 52 analytes. The chiral selectors immobilized on 2.5?μm silica particles were tris-(3,5-dimethylphenylcarmabate) derivatives of cellulose or amylose. The influence of the polysaccharide backbone, different organic modifiers, and different mobile phase additives on retention and enantioseparation was monitored. Conditions for fast baseline enantioseparation were found for the majority of the compounds. The success rate of baseline and partial enantioseparation with cellulose-based chiral stationary phase was 51.9% and 15.4%, respectively. Using amylose-based chiral stationary phase we obtained 76.9% of baseline enantioseparations and 9.6% of partial enantioseparations of the tested compounds. The best results on cellulose-based chiral stationary phase were achieved particularly with propane-2-ol and a mixture of isopropylamine and trifluoroacetic acid as organic modifier and additive to CO2, respectively. Methanol and basic additive isopropylamine were preferred on amylose-based chiral stationary phase. The complementary enantioselectivity of the cellulose- and amylose-based chiral stationary phases allows separation of the majority of the tested structurally different compounds. Separation systems were found to be directly applicable for analyses of biologically active compounds of interest.

Chiral separations of some β-adrenergic agonists and antagonists on AmyCoat column by HPLC

Ali, Imran,Saleem, Kishwar,Gaitonde, Vinay D.,Aboul-Enein, Hassan Y.,Hussain, Iqbal

experimental part, p. 24 - 28 (2010/09/14)

Sixteen β-adrenergic antagonists namely acebutalol, alprenolol, atenolol, bisoprolol, bopindolol, bufurolol, carazolol, celiprolol, indenolol, metaprolol, nebivolol, oxprenolol, practolol, propranolol, tertalol, and timolol, and two β-adrenergic agonists namely cimeterol and clenbuterol were resolved on AmyCoat (150 x 46 mm, 3 μm size of silica particle) by using (85:15:0.1, v/v/v), (90:10:0.1, v/v/v), and (95:05:0.1, v/v/v) combinations of η-heptane, ethanol, and diethylamine solvents, respectively. The flow rates used were 0.5, 1.0, 2.0, and 3.0 ml/min with detection at 225 nm. The values of capacity, separation, and resolution factors ranged from 0.38 to 19.70, 1.08-2.33, and 1.0 and 4.50, respectively. The maximum and minimum resolutions were achieved for celiprolol and bufurolol, respectively. The chiral recognition mechanisms were also discussed. The values of validation parameters were calculated.

Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1 Customer Service

What can I do for you?
Get Best Price

Get Best Price for 62697-41-0