Welcome to LookChem.com Sign In | Join Free

CAS No:123456789    This site contains about 108,618 DataSheet documents.

Position: Index > Categories > Semiconductors and Actives
CAS : 38020-81-4
MSDS  :
 Iodoacetyl chloride
CAS  
:
 38020-81-4
SYNONYMS  
:
 

Section 1 - Chemical Product and Company Identification
MSDS Name: Iodoacetyl chloride
Catalog Numbers: AC389340000
Synonyms:

Company Identification:

              Acros Organics N.V.
              One Reagent Lane
              Fair Lawn, NJ 07410
For information in North America, call: 800-ACROS-01
For emergencies in the US, call CHEMTREC: 800-424-9300

Section 2 - Composition, Information on Ingredients

CAS# Chemical Name Percent EINECS/ELINCS
38020-81-4 Iodoacetyl chloride 253-748-7

Section 3 - Hazards Identification

EMERGENCY OVERVIEW

Not available.
Target Organs: Respiratory system, gastrointestinal system, eyes, skin.


Potential Health Effects
Eye: Causes eye burns.
Skin: Harmful if absorbed through the skin. Causes skin burns.
Ingestion: Harmful if swallowed. Causes gastrointestinal tract burns.
Inhalation: Harmful if inhaled. Causes chemical burns to the respiratory tract.
Chronic: Not available.

Section 4 - First Aid Measures


Eyes: Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid imme diately.
Skin: Get medical aid immediately. Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes.
Ingestion: Do not induce vomiting. Get medical aid immediately.
Inhalation: Get medical aid immediately. Remove from exposure and move to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Notes to Physician: Treat symptomatically and supportively.

Section 5 - Fire Fighting Measures


General Information: As in any fire, wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. Water reactive. Material will react with water and may release a flammable and/or toxic gas.
Extinguishing Media: Use foam, dry chemical, or carbon dioxide. DO NOT USE WATER!
Flash Point: Not available.
Autoignition Temperature: Not available.
Explosion Limits, Lower:Not available.
Upper: Not available.
NFPA Rating: Not published.

Section 6 - Accidental Release Measures


General Information: Use proper personal protective equipment as indicated in Section 8.
Spills/Leaks: Absorb spill with inert material (e.g. vermiculite, sand or earth), then place in suitable container. Wear a self contained breathing apparatus and appropriate personal protection. (See Exposure Controls, Personal Protection section). Do not let this chemical enter the environment.

Section 7 - Handling and Storage


Handling: Do not breathe dust, mist, or vapor. Do not get in eyes, on skin, or on clothing. Do not ingest or inhale. Use and store under nitrogen. Use only in a chemical fume hood.
Storage: Store in a cool, dry place. Store in a tightly closed container. Corrosives area. Store under nitrogen.

Section 8 - Exposure Controls, Personal Protection


Engineering Controls: Facilities storing or utilizing this material should be equipped with an eyewash facility and a safety shower. Use adequate ventilation to keep airborne concentrations low.
Exposure Limits
Chemical Name ACGIH NIOSH OSHA - Final PELs
Iodoacetyl chloride none listed none listed none listed

OSHA Vacated PELs: Iodoacetyl chloride: No OSHA Vacated PELs are listed for this chemical.
Personal Protective Equipment
Eyes: Wear chemical splash goggles.
Skin: Wear appropriate protective gloves to prevent skin exposure.
Clothing: Wear appropriate protective clothing to prevent skin exposure.
Respirators: Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN 149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced.

Section 9 - Physical and Chemical Properties


Physical State: Oil
Appearance: dark reddish brown
Odor: Not available.
pH: Not available.
Vapor Pressure: Not available.
Vapor Density: Not available.
Evaporation Rate:Not available.
Viscosity: Not available.
Boiling Point: 63 - 65 deg C @20mmHg
Freezing/Melting Point:Not available.
Decomposition Temperature:Not available.
Solubility: Not available.
Specific Gravity/Density:Not available.
Molecular Formula:C2H2ClIO
Molecular Weight:204.39

Section 10 - Stability and Reactivity


Chemical Stability: Light sensitive.
Conditions to Avoid: Incompatible materials, light.
Incompatibilities with Other Materials: Strong oxidizing agents, strong bases, strong reducing agents.
Hazardous Decomposition Products: Hydrogen chloride, carbon monoxide, carbon dioxide, hydrogen iodide.
Hazardous Polymerization: Has not been reported

Section 11 - Toxicological Information


RTECS#:      
CAS# 38020-81-4 unlisted.
LD50/LC50:
Not available.

Carcinogenicity:
CAS# 38020-81-4: Not listed by ACGIH, IARC, NTP, or CA Prop 65.

Epidemiology: No data available.
Teratogenicity: No data available.
Reproductive Effects: No data available.
Mutagenicity: No data available.
Neurotoxicity: No data available.
Other Studies:

Section 12 - Ecological Information


Ecotoxicity: No data available. No information available.
Environmental: No information available.
Physical: No information available.
Other: Do not empty into drains.

Section 13 - Disposal Considerations

Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste. US EPA guidelines for the classification determination are listed in 40 CFR Parts 261.3. Additionally, waste generators must consult state and local hazardous waste regulations to ensure complete and accurate classification.
RCRA P-Series: None listed.
RCRA U-Series: None listed.

Section 14 - Transport Information

US DOT Canada TDG
Shipping Name: CORROSIVE LIQUID, TOXIC, N.O.S.* No information available.
Hazard Class: 8
UN Number: UN2922
Packing Group: II

Section 15 - Regulatory Information

US FEDERAL

TSCA
     CAS# 38020-81-4 is not listed on the TSCA inventory. It is for research and development use only.
Health & Safety Reporting List
     None of the chemicals are on the Health & Safety Reporting List.
Chemical Test Rules
     None of the chemicals in this product are under a Chemical Test Rule.
Section 12b
     None of the chemicals are listed under TSCA Section 12b.
TSCA Significant New Use Rule
     None of the chemicals in this material have a SNUR under TSCA.
CERCLA Hazardous Substances and corresponding RQs
     None of the chemicals in this material have an RQ.
SARA Section 302 Extremely Hazardous Substances
     None of the chemicals in this product have a TPQ.
Section 313      No chemicals are reportable under Section 313.
Clean Air Act:
     This material does not contain any hazardous air pollutants.
     This material does not contain any Class 1 Ozone depletors.
     This material does not contain any Class 2 Ozone depletors.
Clean Water Act:
     None of the chemicals in this product are listed as Hazardous Substances under the CWA.
     None of the chemicals in this product are listed as Priority Pollutants under the CWA.
     None of the chemicals in this product are listed as Toxic Pollutants under the CWA.
OSHA:
     None of the chemicals in this product are considered highly hazardous by OSHA.
STATE
     CAS# 38020-81-4 is not present on state lists from CA, PA, MN, MA, FL, or NJ.

California Prop 65

California No Significant Risk Level: None of the chemicals in this product are listed.

European/International Regulations

European Labeling in Accordance with EC Directives
Hazard Symbols:
     C
Risk Phrases:

     R 20/21/22 Harmful by inhalation, in contact with skin and if
     swallowed.
     R 29 Contact with water liberates toxic gas.
     R 34 Causes burns.

Safety Phrases:

     S 26 In case of contact with eyes, rinse immediately with plenty of
     water and seek medical advice.
     S 36/37/39 Wear suitable protective clothing, gloves and eye/face pr
     otection.
     S 45 In case of accident or if you feel unwell, seek medical advice
     immediately (show the label where possible).

WGK (Water Danger/Protection)

     CAS# 38020-81-4: No information available.
Canada - DSL/NDSL
None of the chemicals in this product are listed on the DSL or NDSL list.
Canada - WHMIS
     not available.
This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations and the MSDS contains all of the information required by those regulations.
Canadian Ingredient Disclosure List

Section 16 - Additional Information

MSDS Creation Date: 7/27/2006
Revision #1 Date: 3/26/2008

The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall Fisher be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Fisher has been advised of the possibility of such damages.


Acetyl chloride, iodo-(6CI,9CI)   

Related Product

CAS No.38020-81-4 Iodoacetyl chloride

Assay:98%Min Appearance:detailed in specifications Package:according to the clients requirement Storage:Store in dry, dark and ventilated place. Transportation:by air or by ocean shipping Application:An important raw material and intermediate used in Organic Synthesis, Pharmaceuticals 

Min. Order:0

Supplier:Dayang Chem (Hangzhou) Co.,Ltd. [ China (Mainland)]

Assessed
Supplier

Tel:+86-571-88938639

Address:9/F, Unit 2 Changdi Torch Building, 259# WenSan Road, Xihu District, Hangzhou City 310012, P.R.China

Contact Suppliers

CAS No.38020-81-4 Factory Supply Iodoacetyl chloride

Assay:99% Appearance:powder or granule ( refer to COA) Package:25kgs/fiber drum Storage:Keep in a cool & dry place Transportation:by sea or by air Application:Librium, Valium 

Min. Order:0

Supplier:Ality Chemical Corporation [ China (Mainland)]

Assessed
Supplier

Tel:0513-87616220

Address:Fine chemical industry park, Nantong,Jiangsu

Contact Suppliers

CAS No.38020-81-4 Iodoacetyl chloride

Assay:99.90% Appearance:solid or liquid Package:drum and bag Storage:in sealed air resistant place Transportation:by sea or air Application:for pharma use 

Min. Order:0

Supplier:Kono Chem Co.,Ltd [ China (Mainland)]

Assessed
Supplier

Tel:86-29-86107037-8015

Address:No.11 Daqing Road,Lianhu District,Xi鈥檃n 710082,China

Contact Suppliers

CAS No.38020-81-4 Iodoacetylchloride

Assay:99% Package:25kg/Barrel Storage:ln stock Transportation:Express/Sea/Air Application:Chemicals 

Min. Order:0

Supplier:Hangzhou Sartort Biopharma Co., Ltd [ China (Mainland)]

Assessed
Supplier

Tel:86-571-87039693

Address:No. 57, Tech Park Road, Hangzhou, Zhejiang, China

Contact Suppliers

CAS No.38020-81-4 Acetyl chloride, iodo-(6CI,9CI)

Assay:99% Application:Fine chemical intermediates, used as the main raw material for he synthesis of various pesticides, medicines, surfactants, polymer monomers, Ond Ontifungal agents 

Min. Order:0

Supplier:Antimex Chemical Limied [ China (Mainland)]

Assessed
Supplier

Tel:0086-21-50563169

Address:Room1027,No.Jinyu Road,Pudong

Contact Suppliers

CAS No.38020-81-4 Acetyl chloride, iodo-(6CI,9CI)

Assay:99% Application:Fine chemical intermediates, used as the main raw material for the synthesis of various pesticides, medicines, surfactants, polymer monomers, and antifungal agents 

Min. Order:0

Supplier:Chemlyte Solutions [ China (Mainland)]

Assessed
Supplier

Tel:+86-189 8945 5137

Address:Jian Qiao Community, 789 Shenhua Road, Xihu District, Hangzhou, China, 310000

Contact Suppliers

CAS No.38020-81-4 Acetyl chloride, iodo-(6CI,9CI)

Assay:99% Appearance:liquid or powder  Package:according to the clients requirement Storage:Dry and Cool Place  Transportation:UPS FedEx ,DHL,EXPRESS LINE Application:API 

Min. Order:1Gram

Supplier:Shandong Mopai Biotechnology Co., LTD [ China (Mainland)]

Premium
Supplier

Tel:+86-15965530500

Address:shandong

Contact Suppliers

CAS No.38020-81-4 Iodoacetyl chloride, 97% 38020-81-4

Assay:97% Appearance:solid or liquid Package:As customer require Storage:in sealed air resistant place Transportation:by sea or by airplane Application:Pharma;Industry;Agricultural 

Min. Order:0

Supplier:Hunan Russell Chemicals Technology Co.,Ltd [ China (Mainland)]

Premium
Supplier

Tel:0086-182-2994-0868

Address:Buiding4,Lugu Enterprise Plaza, Yuelu Distric

Contact Suppliers