Welcome to LookChem.com Sign In|Join Free
  • or

Americium SDS

Post Buying Request

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 15, 2017

Revision Date: Aug 15, 2017

1.Identification

1.1 GHS Product identifier

Product name americium atom

1.2 Other means of identification

Product number -
Other names Americium

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only. Radionuclides (radioactive materials)
Uses advised against no data available

1.4 Supplier's details

1.5 Emergency phone number

Emergency phone number -
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

2.Hazard identification

2.1 Classification of the substance or mixture

no data available

2.2 GHS label elements, including precautionary statements

Pictogram(s) no data available
Signal word

no data available

Hazard statement(s)

no data available

Precautionary statement(s)
Prevention

no data available

Response

no data available

Storage

no data available

Disposal

no data available

2.3 Other hazards which do not result in classification

no data available

3.Composition/information on ingredients

3.1 Substances

Chemical name Common names and synonyms CAS number EC number Concentration
americium atom americium atom 7440-35-9 none 100%

4.First-aid measures

4.1 Description of necessary first-aid measures

General advice

Consult a physician. Show this safety data sheet to the doctor in attendance.

If inhaled

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

In case of skin contact

Wash off with soap and plenty of water. Consult a physician.

In case of eye contact

Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

If swallowed

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

4.2 Most important symptoms/effects, acute and delayed

no data available

4.3 Indication of immediate medical attention and special treatment needed, if necessary

Basic Treatment. Establish a patent airway (oropharyngeal or nasopharyngeal airway, if needed). Suction if necessary. Watch for signs of respiratory insufficiency and assist ventilations if necessary. Administer oxygen by nonrebreather mask at 10 to 15 mL/min. Monitor for shock and treat if necessary. Anticipate seizures and treat if necessary. Perform routine emergency care for associated injuries. ... Perform routine basic life support care as necessary. /Radioactives I, II, and III/

5.Fire-fighting measures

5.1 Extinguishing media

Suitable extinguishing media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

5.2 Specific hazards arising from the chemical

no data available

5.3 Special protective actions for fire-fighters

Wear self-contained breathing apparatus for firefighting if necessary.

6.Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures

Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.

6.2 Environmental precautions

Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.

6.3 Methods and materials for containment and cleaning up

Decontamination is most successful when the material can be recycled for use in a nuclear facility since the need to prove releasability (cleanliness) is eliminated. Nevertheless, cleaning material for unrestricted release is also possible in some cases. It may also be possible to decontaminate an item enough to change its classification from TRU/transuranic/ waste to LLW /low-level waste/, thereby allowing immediate disposal of the item, while a relatively small quantity of decontamination waste is stored as TRU waste. Electropolishing to remove the thinnest metal surface has been very effective and produces a relatively small waste volume, especially when one of the wetted sponge units is used rather than an emersion tank. Surface scabbling has been used in decontamination of concrete, and various abrasive blasting methods have also been effective. Strippable and self-stripping coatings may be used to decontaminate surfaces, even though the primary application of strippable coatings has been in preventing contamination of surfaces. /Plutonium facilities/

7.Handling and storage

7.1 Precautions for safe handling

Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure - obtain special instructions before use.Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.

7.2 Conditions for safe storage, including any incompatibilities

Store in cool place. Keep container tightly closed in a dry and well-ventilated place.

8.Exposure controls/personal protection

8.1 Control parameters

Occupational Exposure limit values

no data available

Biological limit values

no data available

8.2 Appropriate engineering controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

8.3 Individual protection measures, such as personal protective equipment (PPE)

Eye/face protection

Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin protection

Wear impervious clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Respiratory protection

Wear dust mask when handling large quantities.

Thermal hazards

no data available

9.Physical and chemical properties

Physical state no data available
Colour Silvery metal /Zero valence americium/
Odour no data available
Melting point/ freezing point 1175oC
Boiling point or initial boiling point and boiling range 2,067°C /Americium metal/
Flammability no data available
Lower and upper explosion limit / flammability limit no data available
Flash point no data available
Auto-ignition temperature no data available
Decomposition temperature no data available
pH no data available
Kinematic viscosity no data available
Solubility Dissolves readily in aq HCl; insoluble in liquid ammonia. /Americium metal/
Partition coefficient n-octanol/water (log value) no data available
Vapour pressure no data available
Density and/or relative density 13.671/Americium metal/
Relative vapour density no data available
Particle characteristics no data available

10.Stability and reactivity

10.1 Reactivity

no data available

10.2 Chemical stability

Am3+ ion /is/ stable; difficult to oxidize. /from table/

10.3 Possibility of hazardous reactions

no data available

10.4 Conditions to avoid

no data available

10.5 Incompatible materials

no data available

10.6 Hazardous decomposition products

no data available

11.Toxicological information

Acute toxicity

  • Oral: no data available
  • Inhalation: no data available
  • Dermal: no data available

Skin corrosion/irritation

no data available

Serious eye damage/irritation

no data available

Respiratory or skin sensitization

no data available

Germ cell mutagenicity

no data available

Carcinogenicity

There is sufficient evidence in experimental animals for the carcinogenicity of mixed alpha-particle emitters (radium-224, radium-226, thorium-227, thorium-228, thorium-230, thorium-232, neptunium-237, plutonium-238, plutonium-239 (together with plutonium- 240), americium-241, curium-244, californium-249 and californium-252). /Radium, Plutonium, Americium, Curium, Californium/

Reproductive toxicity

no data available

STOT-single exposure

no data available

STOT-repeated exposure

no data available

Aspiration hazard

no data available

12.Ecological information

12.1 Toxicity

  • Toxicity to fish: no data available
  • Toxicity to daphnia and other aquatic invertebrates: no data available
  • Toxicity to algae: no data available
  • Toxicity to microorganisms: no data available

12.2 Persistence and degradability

no data available

12.3 Bioaccumulative potential

Fish may take up americium, but little builds up in the fleshy tissue(1). BCF values for americium-241 measured for various fish at the Department of Energy's Savannah River Site, SC were reported in 1996 as follows: largemouth bass (muscle), 2,500; bullhead catfish (bone), 4,200. In a study performed at a nuclear waste pond at Hanford, WA, the maximum concentration of actinides, including americium-241, that would accumulate in the whole fish and fish fillet were measured. In this waste pond, the sediment concentration of americium-241 was about 5.5 Bq/g, approximately 3 orders of magnitude above background levels. Both the bluegill and largemouth bass were studied. The concentration of americium-241 in the water was about 7 uBq/mL. The results from the Hanford study indicate that both short- and long-term uptakes of americium were low; that uptake was similar for short-term (5 days) and long-term (430 days) experiments; and that direct sediment-to-fish transfer was the primary route for americium uptake. In both species of fish, there were only a few cases where fillet concentrations were >10 times those in controls. The maximum concentration of americium-241 obtained in bass and bluegill were 1.1 and 1.0 mBq/mL dry weight in fillet and 2.5 and 74 mBq/mL in whole fish(1).

12.4 Mobility in soil

Americium has been shown to be largely associated with the high molecular weight organic factions of dissolved organic matter in the soil solution of two grassland soils, a soddy podzolic soil and a peat soil, in the vicinity of the nuclear reactor at Chernobyl, Ukraine. The distribution coefficients for americium-241 in these soils were (soil type (depth), Kd in mL/g): soddy podzolic-sod layer (0 to 2 cm), 1,220; soddy podzolic-mineral layer (2 to 5 cm), 810; peat (0 to 2 cm), 2,760; and peat (2 to 5 cm), 4,550(1). While it was similarly shown that the concentration of americium-241 was 2 to 3 times higher in organic matter than in whole sediment from Lake Michigan, organic matter was a very minor constituent of the sediment (<0.5%), so organic matter was associated with a smaller percentage of americium despite its higher concentration. The bulk of the americium-241 in Lake Michigan was found in the hydrous oxides fraction of both the sediment core samples and the suspended particulate matter(1).

12.5 Other adverse effects

no data available

13.Disposal considerations

13.1 Disposal methods

Product

The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.

Contaminated packaging

Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.

14.Transport information

14.1 UN Number

ADR/RID: no data available IMDG: no data available IATA: no data available

14.2 UN Proper Shipping Name

ADR/RID: no data available
IMDG: no data available
IATA: no data available

14.3 Transport hazard class(es)

ADR/RID: no data available IMDG: no data available IATA: no data available

14.4 Packing group, if applicable

ADR/RID: no data available IMDG: no data available IATA: no data available

14.5 Environmental hazards

ADR/RID: no IMDG: no IATA: no

14.6 Special precautions for user

no data available

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

no data available

15.Regulatory information

15.1 Safety, health and environmental regulations specific for the product in question

Chemical name Common names and synonyms CAS number EC number
americium atom americium atom 7440-35-9 none
European Inventory of Existing Commercial Chemical Substances (EINECS) Listed.
EC Inventory Listed.
United States Toxic Substances Control Act (TSCA) Inventory Listed.
China Catalog of Hazardous chemicals 2015 Not Listed.
New Zealand Inventory of Chemicals (NZIoC) Not Listed.
Philippines Inventory of Chemicals and Chemical Substances (PICCS) Not Listed.
Vietnam National Chemical Inventory Not Listed.
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) Not Listed.

16.Other information

Information on revision

Creation Date Aug 15, 2017
Revision Date Aug 15, 2017

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

  • IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
  • HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
  • IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
  • eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
  • CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
  • ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
  • ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
  • Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
  • ECHA - European Chemicals Agency, website: https://echa.europa.eu/

Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.
Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1 Customer Service

What can I do for you?
Get Best Price

Get Best Price for 7440-35-9