1.Identification

1.1 GHS Product identifier

Product name Antimony pentafluoride

1.2 Other means of identification

Product number -
Other names pentafluoro-λ<sup>5</sup>-stibane

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only.
Uses advised against no data available

1.4 Supplier's details

1.5 Emergency phone number

Emergency phone number -
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

2.Hazard identification

2.1 Classification of the substance or mixture

Hazardous to the aquatic environment, long-term (Chronic) - Category Chronic 3

2.2 GHS label elements, including precautionary statements

Pictogram(s) No symbol.
Signal word

No signal word.

Hazard statement(s)

H412 Harmful to aquatic life with long lasting effects

Precautionary statement(s)
Prevention

P273 Avoid release to the environment.

Response

none

Storage

none

Disposal

P501 Dispose of contents/container to ...

2.3 Other hazards which do not result in classification

none

3.Composition/information on ingredients

3.1 Substances

Chemical name Common names and synonyms CAS number EC number Concentration
Antimony pentafluoride Antimony pentafluoride 7783-70-2 none 100%

4.First-aid measures

4.1 Description of necessary first-aid measures

General advice

Consult a physician. Show this safety data sheet to the doctor in attendance.

If inhaled

Fresh air, rest. Half-upright position. Refer immediately for medical attention. See Notes.

In case of skin contact

Remove contaminated clothes. Rinse skin with plenty of water or shower. Refer immediately for medical attention. Apply calcium gluconate to the burn areas.

In case of eye contact

Rinse with plenty of water for several minutes (remove contact lenses if easily possible). Refer immediately for medical attention.

If swallowed

Rinse mouth. Do NOT induce vomiting. Refer immediately for medical attention.

4.2 Most important symptoms/effects, acute and delayed

The compound is irritating to eyes, skin, and lungs. Contact with eyes or skin causes severe burns. The compound is extremely toxic with a probable oral lethal dose of 5-50 mg/kg or between 7 drops and one teaspoonful for a 150 pound person (antimony salts). (EPA, 1998)

4.3 Indication of immediate medical attention and special treatment needed, if necessary

Absorption, Distribution and Excretion

DISTRIBUTION IN RATS AFTER CHRONIC POISONING BY INHALATION OF ANTIMONY PENTAFLUORIDE SHOWED HIGH ANTIMONY CONCN IN BLOOD. LEVELS IN LIVER, KIDNEYS, SPLEEN AND PANCREAS WERE SIMILAR. THE ANTIMONY WAS RETAINED FOR A LONG TIME AND COULD BE DETECTED IN ORGANS UNDER EXAMINATION ONE MONTH AFTER EXPERIMENT DISCONTINUED.

5.Fire-fighting measures

5.1 Extinguishing media

Suitable extinguishing media

Approach fire from upwind to avoid hazardous vapors & toxic decomposition products. Use dry chemical, carbon dioxide or flooding quantities of water as spray on fire involved material.

5.2 Specific hazards arising from the chemical

Reacts violently with water, to form poisonous hydrogen fluoride fumes. If confined and wet can cause explosion. May cause fire in contact with combustible material. Hazardous polymerization may not occur. (EPA, 1998)

5.3 Special protective actions for fire-fighters

Wear self-contained breathing apparatus for firefighting if necessary.

6.Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures

Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.

6.2 Environmental precautions

Evacuate danger area! Consult an expert! Personal protection: complete protective clothing including self-contained breathing apparatus. Collect leaking and spilled liquid in sealable containers as far as possible. Do NOT wash away into sewer. Do NOT absorb in saw-dust or other combustible absorbents. Do NOT let this chemical enter the environment. Then store and dispose of according to local regulations.

6.3 Methods and materials for containment and cleaning up

Pick up and arrange disposal. Sweep up and shovel. Keep in suitable, closed containers for disposal.

7.Handling and storage

7.1 Precautions for safe handling

Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure - obtain special instructions before use.Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.

7.2 Conditions for safe storage, including any incompatibilities

Separated from combustible substances, reducing agents and food and feedstuffs. Dry. Well closed. Keep in a well-ventilated room. Do NOT store or transport in containers made from metal or glass. Provision to contain effluent from fire extinguishing. Store in an area without drain or sewer access.Store in a cool, dry, well-ventilated location. Outside or detached storage is preferred. Separate from organic or siliceous materials.

8.Exposure controls/personal protection

8.1 Control parameters

Occupational Exposure limit values

Recommended Exposure Limit: 10 Hr Time-Weighted Avg 0.5 mg/cu m. /Antimony/

Biological limit values

no data available

8.2 Appropriate engineering controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

8.3 Individual protection measures, such as personal protective equipment (PPE)

Eye/face protection

Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin protection

Wear impervious clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Respiratory protection

Wear dust mask when handling large quantities.

Thermal hazards

no data available

9.Physical and chemical properties

Physical state clear, colorless liquid.
Colour MODERATELY VISCOUS LIQUID
Odour SHARP ODOR
Melting point/ freezing point 7oC(lit.)
Boiling point or initial boiling point and boiling range 148-150°C(lit.)
Flammability Not combustible but enhances combustion of other substances. Gives off irritating or toxic fumes (or gases) in a fire.
Lower and upper explosion limit / flammability limit no data available
Flash point 149.5oC
Auto-ignition temperature no data available
Decomposition temperature no data available
pH no data available
Kinematic viscosity 0.768 cp @ 24.4°C (est)
Solubility Sol in potassium fluoride (KF), liquid sulfur dioxide
Partition coefficient n-octanol/water (log value) no data available
Vapour pressure 10 mm Hg ( 25 °C)
Density and/or relative density 2.993g/mLat 25°C(lit.)
Relative vapour density 2.2 (vs air)
Particle characteristics no data available

10.Stability and reactivity

10.1 Reactivity

no data available

10.2 Chemical stability

Stable under recommended storage conditions.

10.3 Possibility of hazardous reactions

ANTIMONY PENTAFLUORIDE is strongly acidic. Reacts vigorously with bases. When heated to decomposition, it emits highly toxic fumes of fluorides and metallic antimony. Reacts with ammonia to form a diammoniate.

10.4 Conditions to avoid

no data available

10.5 Incompatible materials

REACTS VIOLENTLY WITH WATER. ALSO FORMS A SOLID DIHYDRATE, WHICH REACTS VIOLENTLY WITH MORE WATER TO FORM A CLEAR SOLN.

10.6 Hazardous decomposition products

When heated to decomp it emits very toxic fumes of /hydrogen fluoride/ and antimony.

11.Toxicological information

Acute toxicity

  • Oral: no data available
  • Inhalation: no data available
  • Dermal: no data available

Skin corrosion/irritation

no data available

Serious eye damage/irritation

no data available

Respiratory or skin sensitization

no data available

Germ cell mutagenicity

no data available

Carcinogenicity

A4; Not classifiable as a human carcinogen. /Fluorides, as F/

Reproductive toxicity

no data available

STOT-single exposure

no data available

STOT-repeated exposure

no data available

Aspiration hazard

no data available

12.Ecological information

12.1 Toxicity

  • Toxicity to fish: no data available
  • Toxicity to daphnia and other aquatic invertebrates: no data available
  • Toxicity to algae: no data available
  • Toxicity to microorganisms: no data available

12.2 Persistence and degradability

no data available

12.3 Bioaccumulative potential

no data available

12.4 Mobility in soil

no data available

12.5 Other adverse effects

no data available

13.Disposal considerations

13.1 Disposal methods

Product

The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.

Contaminated packaging

Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.

14.Transport information

14.1 UN Number

ADR/RID: UN1732 IMDG: UN1732 IATA: UN1732

14.2 UN Proper Shipping Name

ADR/RID: ANTIMONY PENTAFLUORIDE
IMDG: ANTIMONY PENTAFLUORIDE
IATA: ANTIMONY PENTAFLUORIDE

14.3 Transport hazard class(es)

ADR/RID: 6.1 IMDG: 6.1 IATA: 6.1

14.4 Packing group, if applicable

ADR/RID: II IMDG: II IATA: II

14.5 Environmental hazards

ADR/RID: no IMDG: no IATA: no

14.6 Special precautions for user

no data available

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

no data available

15.Regulatory information

15.1 Safety, health and environmental regulations specific for the product in question

Chemical name Common names and synonyms CAS number EC number
Antimony pentafluoride Antimony pentafluoride 7783-70-2 none
European Inventory of Existing Commercial Chemical Substances (EINECS) Listed.
EC Inventory Listed.
United States Toxic Substances Control Act (TSCA) Inventory Listed.
China Catalog of Hazardous chemicals 2015 Listed.
New Zealand Inventory of Chemicals (NZIoC) Listed.
Philippines Inventory of Chemicals and Chemical Substances (PICCS) Listed.
Vietnam National Chemical Inventory Not Listed.
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) Listed.

16.Other information

Information on revision

Creation Date Aug 16, 2017
Revision Date Aug 16, 2017

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

  • IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
  • HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
  • IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
  • eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
  • CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
  • ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
  • ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
  • Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
  • ECHA - European Chemicals Agency, website: https://echa.europa.eu/

Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.
Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1

What can I do for you?
Get Best Price

Get Best Price for 7783-70-2