Welcome to LookChem.com Sign In|Join Free

CAS

  • or

52605-12-6

Post Buying Request

52605-12-6 Suppliers

Recommended suppliersmore

  • Product
  • FOB Price
  • Min.Order
  • Supply Ability
  • Supplier
  • Contact Supplier

52605-12-6 Usage

Check Digit Verification of cas no

The CAS Registry Mumber 52605-12-6 includes 8 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 5 digits, 5,2,6,0 and 5 respectively; the second part has 2 digits, 1 and 2 respectively.
Calculate Digit Verification of CAS Registry Number 52605-12:
(7*5)+(6*2)+(5*6)+(4*0)+(3*5)+(2*1)+(1*2)=96
96 % 10 = 6
So 52605-12-6 is a valid CAS Registry Number.
InChI:InChI=1/C20H22O8/c1-23-13-7-11(8-14(24-2)19(13)27-5)17(21)18(22)12-9-15(25-3)20(28-6)16(10-12)26-4/h7-10H,1-6H3

52605-12-6Relevant articles and documents

Space-conjugated organic molecule based on hexaarylbenzene skeleton and preparation and application thereof

-

, (2018/11/22)

The invention belongs to the technical field of organic electronics, and discloses a space-conjugated organic molecule based on a hexaarylbenzene skeleton and preparation and application thereof. Thespace-conjugated organic molecular structure based on th

Polysiloxanes-based stationary phases containing methoxy-substituted tetraphenyl-phenyl groups for gas chromotographic separations

He, Xinxin,Han, Xue,Wang, Huan,Wang, Bing,Wu, Bo

, p. 76514 - 76523 (2016/08/30)

3,4-Di(4-methoxy phenyl)-2,5-diphenyl phenyl grafted polysiloxane (MTP) and 3,4-di(3,4,5-trimethoxy phenyl)-2,5-diphenyl phenyl grafted polysiloxane (TMP) were synthesized and statically coated on fused silica capillary columns. The MTP and TMP columns have efficiencies of almost 3400 (k = 3.74, 0.25 mm i.d.) and 3600 (k = 3.96, 0.25 mm i.d.) plates per m, respectively, which are determined by naphthalene at 120 °C. Both columns exhibited moderate polarity based on the McReynolds constants. The separation of the polyethylene pyrolysis products shows that the maximum operating temperature of the two columns can reach up to 360 °C and 370 °C, respectively. In addition, the solvation parameter indicated that the dipole-induced dipole, H-bond alkaline, and dispersive interactions were the main interactions between the solutes and the stationary phases. The separation performance of the new columns was evaluated by gas chromatography separation of the Grob test mixtures. Several mixtures with π-conjugated structure were also well separated on the new columns. This work demonstrated the promising future of the new type of stationary phases in GC analysis.

Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1

What can I do for you?
Get Best Price

Get Best Price for 52605-12-6