Welcome to LookChem.com Sign In|Join Free

CAS

  • or

1194056-02-4

Post Buying Request

1194056-02-4 Suppliers

Recommended suppliersmore

This product is a nationally controlled contraband, and the Lookchem platform doesn't provide relevant sales information.

1194056-02-4 Usage

Check Digit Verification of cas no

The CAS Registry Mumber 1194056-02-4 includes 10 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 7 digits, 1,1,9,4,0,5 and 6 respectively; the second part has 2 digits, 0 and 2 respectively.
Calculate Digit Verification of CAS Registry Number 1194056-02:
(9*1)+(8*1)+(7*9)+(6*4)+(5*0)+(4*5)+(3*6)+(2*0)+(1*2)=144
144 % 10 = 4
So 1194056-02-4 is a valid CAS Registry Number.

1194056-02-4Downstream Products

1194056-02-4Relevant articles and documents

Enantiomeric separation of Novel Psychoactive Substances by capillary electrophoresis using (+)-18-crown-6-tetracarboxylic acid as chiral selector

H?gele, Johannes S.,Schmid, Martin G.

, p. 1019 - 1026 (2018/07/29)

In the recent years, hundreds of Novel Psychoactive Substances (NPS) have entered both the European and the global drug market. These drugs, which are mainly used for recreational matters, have caused serious social problems. Every year, the spectrum of these misused drugs is enlarged by new derivatives, which are produced by modifications of basic structures of already well-known substances. Additionally, a lot of them possess a stereogenic center which leads to 2 enantiomeric forms. The fact that the pharmacological effects and potencies of the enantiomers of these chiral NPS may differ can be assumed from a broad spectrum of active pharmaceutical ingredients. For this reason, analytical method development regarding enantiomeric separation for these classes of substances is of great pharmaceutical and medical interest. The aim of this work was to create an easy-to-prepare chiral capillary electrophoresis method for the enantioseparation of NPS which contains a primary amino group by means of (+)-18-crown-6-tetracarboxylic acid as chiral selector. Novel Psychoactive Substances were purchased at various Internet stores or represent samples seized by Austrian police. The effects of selector concentration, the electrolyte composition, and the addition of organic modifiers to the background electrolyte on enantioseparation were investigated. Under optimized conditions, the use of 20-mM (+)-18-crown-6-tetracarboxylic acid, 10-mM Tris, and 30-mM citric acid buffer at pH 2.10 turned out to be effective. Fifteen of 24 tested NPS were resolved in their enantiomers within 15?minutes. It was found that all NPS were traded as racemic mixtures.

Enantioselective potential of polysaccharide-based chiral stationary phases in supercritical fluid chromatography

Kucerova, Gabriela,Kalikova, Kveta,Tesarova, Eva

supporting information, p. 239 - 246 (2017/05/29)

The enantioselective potential of two polysaccharide-based chiral stationary phases for analysis of chiral structurally diverse biologically active compounds was evaluated in supercritical fluid chromatography using a set of 52 analytes. The chiral selectors immobilized on 2.5?μm silica particles were tris-(3,5-dimethylphenylcarmabate) derivatives of cellulose or amylose. The influence of the polysaccharide backbone, different organic modifiers, and different mobile phase additives on retention and enantioseparation was monitored. Conditions for fast baseline enantioseparation were found for the majority of the compounds. The success rate of baseline and partial enantioseparation with cellulose-based chiral stationary phase was 51.9% and 15.4%, respectively. Using amylose-based chiral stationary phase we obtained 76.9% of baseline enantioseparations and 9.6% of partial enantioseparations of the tested compounds. The best results on cellulose-based chiral stationary phase were achieved particularly with propane-2-ol and a mixture of isopropylamine and trifluoroacetic acid as organic modifier and additive to CO2, respectively. Methanol and basic additive isopropylamine were preferred on amylose-based chiral stationary phase. The complementary enantioselectivity of the cellulose- and amylose-based chiral stationary phases allows separation of the majority of the tested structurally different compounds. Separation systems were found to be directly applicable for analyses of biologically active compounds of interest.