Welcome to LookChem.com Sign In|Join Free

CAS

  • or

1606-67-3

Post Buying Request

1606-67-3 Suppliers

Recommended suppliersmore

  • Product
  • FOB Price
  • Min.Order
  • Supply Ability
  • Supplier
  • Contact Supplier

1606-67-3 Usage

Chemical Properties

yellow-green powder

Uses

Different sources of media describe the Uses of 1606-67-3 differently. You can refer to the following data:
1. It acts as a precursor molecule for production of other fluorescent probes such as 1-Azidopyrene, APTS, and N-(1-Pyrene)iodoacetamide.
2. 1-Aminopyrene is used in the synthesis of novel fluorescent nanoscale ionic silicate platelets for use in bacterial detection and other biosensor applications.

General Description

Colorless crystals. Yellow needles from hexane, melting point 117-8°C.

Reactivity Profile

1-Aminopyrene neutralizes acids in exothermic reactions to form salts plus water. May be incompatible with isocyanates, halogenated organics, peroxides, phenols (acidic), epoxides, anhydrides, and acid halides. May generate hydrogen, a flammable gas, in combination with strong reducing agents such as hydrides.

Fire Hazard

1-Aminopyrene is probably combustible.

Purification Methods

1-Aminopyrene [1606-67-3] M 217.3, m 117-118o, pK 1 2.91 (50% aqueous EtOH), pK 2 2.77 (50% aqueous EtOH). Crystallise it from hexane. [Beilstein 12 IV 3460.]

Check Digit Verification of cas no

The CAS Registry Mumber 1606-67-3 includes 7 digits separated into 3 groups by hyphens. The first part of the number,starting from the left, has 4 digits, 1,6,0 and 6 respectively; the second part has 2 digits, 6 and 7 respectively.
Calculate Digit Verification of CAS Registry Number 1606-67:
(6*1)+(5*6)+(4*0)+(3*6)+(2*6)+(1*7)=73
73 % 10 = 3
So 1606-67-3 is a valid CAS Registry Number.
InChI:InChI=1/C16H11N/c17-14-9-7-12-5-4-10-2-1-3-11-6-8-13(14)16(12)15(10)11/h1-9H,17H2

1606-67-3 Well-known Company Product Price

  • Brand
  • (Code)Product description
  • CAS number
  • Packaging
  • Price
  • Detail
  • Alfa Aesar

  • (43968)  1-Aminopyrene, 97%   

  • 1606-67-3

  • 0.5g

  • 433.0CNY

  • Detail
  • Alfa Aesar

  • (43968)  1-Aminopyrene, 97%   

  • 1606-67-3

  • 2g

  • 1676.0CNY

  • Detail

1606-67-3SDS

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 10, 2017

Revision Date: Aug 10, 2017

1.Identification

1.1 GHS Product identifier

Product name 1-Aminopyrene

1.2 Other means of identification

Product number -
Other names pyren-1-amine

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only.
Uses advised against no data available

1.4 Supplier's details

1.5 Emergency phone number

Emergency phone number -
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

More Details:1606-67-3 SDS

1606-67-3Related news

An optical sensor based on covalent immobilization of 1-Aminopyrene (cas 1606-67-3) using Au nanoparticles as bridges and carriers07/23/2019

A novel technique of covalent immobilization of indicator dyes for the preparation of optical sensors is investigated. Au nanoparticles are used as bridges and carriers for anchoring indicator dyes on the surfaces of quartz glass slides (the substrates). 1-Aminopyrene was covalently attached to ...detailed

Morphology directing synthesis of 1-Aminopyrene (cas 1606-67-3) microstructures and its super quenching effect towards nitro aromatics07/19/2019

Morphologically interesting microstructures of 1-aminopyrene (1-PyNH2) are synthesized using re-precipitation method. Two and three dimensional microparticles are obtained in presence of cetyl trimethyl ammonium bromide (CTAB) as morphology directing agent. One dimensional wire shaped microparti...detailed

Measurement of urinary 1-Aminopyrene (cas 1606-67-3) and 1-hydroxypyrene as biomarkers of exposure to diesel particulate matter in gold miners07/18/2019

Metabolites of polycyclic aromatic hydrocarbons measured in human samples are often used as biomarkers of exposure to diesel engine exhaust (DEE). The aim of this study was to assess the changes in urinary levels of 1-aminopyrene (1-AP) and 1-hydroxypyrene (1-OHP) and their relationship with Ele...detailed

1606-67-3Relevant articles and documents

Highly selective turn-on probe for H2S with imaging applications in vitro and in vivo

Thirumalaivasan, Natesan,Venkatesan, Parthiban,Wu, Shu-Pao

, p. 13510 - 13515 (2017)

Hydrogen sulfide (H2S) is the third endogenous gaseous signaling molecule, and its distribution affects several biological processes. To clarify the roles of H2S in living systems, the exact determination of H2S in living cells in vivo has become an important issue. Herein, we report a novel pyrene-based fluorescent probe, PyN3, as a H2S turn-on sensor via reduction of azide to amine, which subsequently undergoes self-immolation through intramolecular 1,6-elimination of the p-aminobenzyl moiety, releasing 1-aminopyrene and leading to the recovery of fluorescence intensity. With its high sensitivity, good selectivity, and low cytotoxicity, PyN3 was able to recognize both exogenous and endogenously produced H2S in biological systems. In contrast to the traditional azide-based H2S probes, PyN3 shows efficient and effective selectivity to H2S at biological pH ranges. Because of these promising properties, PyN3 is an excellent probe for visualizing endogenous H2S in vitro and in vivo.

A new processable and fluorescent polydithienylpyrrole electrochrome with pyrene appendages

Tirke?, Seha,Mersini, Jetmire,?zta?, Zahide,Algi, Melek Pamuk,Algi, Fatih,Cihaner, Atilla

, p. 295 - 301 (2013)

A new hybrid compound, namely 1-(pyren-3-yl)-2,5-di(thiophen-2-yl)-1H- pyrrole (SNS-P), was polymerized via both chemical and electrochemical methods. Chemically obtained soluble polydithienylpyrrole (c-PSNS-P) bearing pyrene appendages is a homogeneous and uniform polymer with a number averaged molecular weight of 15,200 g/mol. The polymer exhibits both multi-electrochromic and fluorescent properties. Upon oxidation, the color of electrochemically obtained polymer (e-PSNS-P) changes from yellowish orange to greenish yellow and to green/blue and finally to blue. In addition, the polymer induces yellowish orange (564 nm) and bright orange emission (613 nm) in solution and solid states, respectively.

1,3-Bis(pyren-1-yliminomethyl)calix[4]arene as a selective fluorescent turn-on sensor for mercury(II) ion

Tanaka, Shinya,Hirasawa, Kengo,Watanabe, Kyohei,Hattori, Tetsutaro

, p. 179 - 183 (2018)

A novel calixarene-based diimine, 1,3-bis(pyren-1-yliminomethyl)calix[4]arene (5), serves as a turn-on-type fluorescent sensor, which selectively detects Hg2+ in THF/H2O (99:1, v/v) in the presence of various other metal ions. Such selectivity is not seen with half salen 1 derived from salicylaldehyde and 1-aminopyrene. 1H NMR analysis reveals that it is a chemodosimetric sensor based on its hydrolysis mediated by Hg2+ to release 1-aminopyrene molecules as fluorescent chromophores.

A new pyrene-based Schiff-base: A selective colorimetric and fluorescent chemosensor for detection of Cu(II) and Fe(III)

Bhorge, Yeshwant Ramchandra,Tsai, Haw-Tyng,Huang, Keh-Feng,Pape, Albert J.,Janaki, Sudhakar Narasimha,Yen, Yao-Pin

, p. 7 - 12 (2014)

A new receptor 1 was prepared, for the detection of Cu2+ and Fe3+ in solutions as a colorimetric and fluorescent sensor, respectively. Receptor 1 shows highly selective and sensitive recognition toward Cu2+ and Fe3+ by naked eye UV-Vis and fluorescent color changes in aqueous solution (DMSO/H2O = 8/2, v/v), respectively. The sensitivity toward Cu2+ or Fe3+ was not interfered with by the presence of other metal ions such as Mg2+, Cd2+, Ag+, Zn2+, Ni2+, Co2+, Mn 2+, Cr3+, Ca2+, Na+, Pb 2+, K+, Fe2+, Li+ and Hg 2+ ions. Receptor 1 can be used for semi-quantitative recognition of Cu2+ ions at ppm level. The fluorescence microscopy experiments showed that the receptor is efficient for detection of Fe3+ in vitro, developing a good image of the biological organelles.

Uncovering the true mechanism of optical detection of HSO4 - in water by Schiff-base receptors - Hydrolysis vs. hydrogen bonding

Kumar, Virendra,Kumar, Ajit,Diwan, Uzra,Upadhyay

, p. 9540 - 9542 (2012)

The mechanism of optical detection of HSO4- in aqueous medium by Schiff-base receptors has previously been proposed to depend on selective hydrogen-bond interactions. Here, we clearly demonstrate for the first time that the acidic na

-

Goldschmiedt

, p. 580 (1881)

-

Tuning of n- and p-type reduced graphene oxide transistors with the same molecular backbone

Lee, Junghyun,Hwang, Eunhee,Lee, Eunkyo,Seo, Sohyeon,Lee, Hyoyoung

, p. 5155 - 5159 (2012)

Play the field: A field-effect transistor using reduced graphene oxides was prepared through the reduction of graphene oxides connected between two electrodes. The use of pyrene with an electron-withdrawing group and an electron-donating group showed the p- and n-doping effects, respectively, while the pyrene backbone with no electron-withdrawing or -donating groups showed no doping effect.

Cobalt-Catalyzed Direct Carbonylative Synthesis of Free (NH)-Benzo[ cd]indol-2(1 H)-ones from Naphthylamides

Ying, Jun,Fu, Lu-Yang,Zhong, Guoqiang,Wu, Xiao-Feng

, p. 5694 - 5698 (2019/07/08)

A cobalt-catalyzed C-H carbonylation of naphthylamides for the synthesis of benzo[cd]indol-2(1H)-one scaffolds has been developed. The reaction employs a traceless directing group and uses benzene-1,3,5-triyl triormate as the CO source, affording various free (NH)-benzo[cd]indol-2(1H)-ones in moderate to high yields (up to 88%). Using this protocol, the total synthesis of BET bromodomain inhibitors A and B was accomplished as well.

Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1

What can I do for you?
Get Best Price

Get Best Price for 1606-67-3