2964-04-7Relevant articles and documents
In-situ and one-step preparation of protein film in capillary column for open tubular capillary electrochromatography enantioseparation
Li, Ling,Xue, Xuqi,Zhang, Huige,Lv, Wenjuan,Qi, Shengda,Du, Hongying,Manyande, Anne,Chen, Hongli
supporting information, p. 2139 - 2142 (2021/04/07)
In this work, the phase-transitioned BSA (PTB) film using the mild and fast fabrication process adhered to the capillary inner wall uniformly, and the fabricated PTB film-coated capillary column was applied to realize open tubular capillary electrochromatography (OT-CEC) enantioseparation. The enantioseparation ability of PTB film-coated capillary was evaluated with eight pairs of chiral analytes including drugs and neurotransmitters, all achieving good resolution and symmetrical peak shape. For three consecutive runs, the relative standard deviations (RSD) of migration time for intra-day, inter-day, and column-to-column repeatability were in the range of 0.3%–3.5%, 0.2%–4.9% and 2.1%–7.7%, respectively. Moreover, the PTB film-coated capillary column ran continuously over 300 times with high separation efficiency. Therefore, the coating method based on BSA self-assembly supramolecular film can be extended to the preparation of other proteinaceous capillary columns.
Effect of basic and acidic additives on the separation of some basic drug enantiomers on polysaccharide-based chiral columns with acetonitrile as mobile phase
Gogaladze, Khatuna,Chankvetadze, Lali,Tsintsadze, Maia,Farkas, Tivadar,Chankvetadze, Bezhan
, p. 228 - 234 (2015/03/18)
The separation of enantiomers of 16 basic drugs was studied using polysaccharide-based chiral selectors and acetonitrile as mobile phase with emphasis on the role of basic and acidic additives on the separation and elution order of enantiomers. Out of the studied chiral selectors, amylose phenylcarbamate-based ones more often showed a chiral recognition ability compared to cellulose phenylcarbamate derivatives. An interesting effect was observed with formic acid as additive on enantiomer resolution and enantiomer elution order for some basic drugs. Thus, for instance, the enantioseparation of several β-blockers (atenolol, sotalol, toliprolol) improved not only by the addition of a more conventional basic additive to the mobile phase, but also by the addition of an acidic additive. Moreover, an opposite elution order of enantiomers was observed depending on the nature of the additive (basic or acidic) in the mobile phase.
Application of cyclam-capped β-cyclodextrin-bonded silica particles as a chiral stationary phase in capillary electrochromatography for enantiomeric separations
Gong, Yinhan,Lee, Hian Kee
, p. 1348 - 1354 (2007/10/03)
Two novel types of substituted cyclam-capped β-cyclodextrin (β-CD)-bonded silica particles have been prepared and used as chiral stationary phases in capillary electrochromatography (CEC). The two stationary phases have a chiral selector with three recognition sites: β-CD, cyclam, and the latter's sidearm. They exhibit excellent enantioselectivities in CEC for a wide range of compounds as a result of the cooperative functioning of the anchored β-CD and cyclam. After inclusion of the metal ion (Ni2+) from the running buffer into the substituted cyclams and their sidearm ligands, the bonded stationary phases become positively charged and can provide extra electrostatic interactions with ionizable solutes and enhance the dipolar interactions with some polar neutral solutes. This enhances the host-guest interaction with some solutes and improves chiral recognition and enantioselectivity. These new types of stationary phases exhibit great potential for fast chiral separations in CEC.