Welcome to LookChem.com Sign In|Join Free
  • or

Glycidol SDS

Post Buying Request

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 15, 2017

Revision Date: Aug 15, 2017

1.Identification

1.1 GHS Product identifier

Product name glycidol

1.2 Other means of identification

Product number -
Other names 2,3-Epoxy-1-propanol

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only.
Uses advised against no data available

1.4 Supplier's details

1.5 Emergency phone number

Emergency phone number -
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

2.Hazard identification

2.1 Classification of the substance or mixture

Acute toxicity - Oral, Category 4

Acute toxicity - Dermal, Category 4

Skin irritation, Category 2

Eye irritation, Category 2

Acute toxicity - Inhalation, Category 3

Specific target organ toxicity – single exposure, Category 3

Germ cell mutagenicity, Category 2

Carcinogenicity, Category 1B

Reproductive toxicity, Category 1B

2.2 GHS label elements, including precautionary statements

Pictogram(s)
Signal word

Danger

Hazard statement(s)

H302 Harmful if swallowed

H312 Harmful in contact with skin

H315 Causes skin irritation

H319 Causes serious eye irritation

H331 Toxic if inhaled

H335 May cause respiratory irritation

H341 Suspected of causing genetic defects

H350 May cause cancer

H360F

Precautionary statement(s)
Prevention

P264 Wash ... thoroughly after handling.

P270 Do not eat, drink or smoke when using this product.

P280 Wear protective gloves/protective clothing/eye protection/face protection.

P261 Avoid breathing dust/fume/gas/mist/vapours/spray.

P271 Use only outdoors or in a well-ventilated area.

P201 Obtain special instructions before use.

P202 Do not handle until all safety precautions have been read and understood.

Response

P301+P312 IF SWALLOWED: Call a POISON CENTER/doctor/…if you feel unwell.

P330 Rinse mouth.

P302+P352 IF ON SKIN: Wash with plenty of water/...

P312 Call a POISON CENTER/doctor/…if you feel unwell.

P321 Specific treatment (see ... on this label).

P362+P364 Take off contaminated clothing and wash it before reuse.

P332+P313 If skin irritation occurs: Get medical advice/attention.

P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

P337+P313 If eye irritation persists: Get medical advice/attention.

P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.

P311 Call a POISON CENTER/doctor/…

P308+P313 IF exposed or concerned: Get medical advice/ attention.

Storage

P403+P233 Store in a well-ventilated place. Keep container tightly closed.

P405 Store locked up.

Disposal

P501 Dispose of contents/container to ...

2.3 Other hazards which do not result in classification

none

3.Composition/information on ingredients

3.1 Substances

Chemical name Common names and synonyms CAS number EC number Concentration
glycidol glycidol 556-52-5 none 100%

4.First-aid measures

4.1 Description of necessary first-aid measures

General advice

Consult a physician. Show this safety data sheet to the doctor in attendance.

If inhaled

Fresh air, rest. Refer for medical attention.

In case of skin contact

Remove contaminated clothes. Rinse skin with plenty of water or shower.

In case of eye contact

First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.

If swallowed

Rinse mouth. Do NOT induce vomiting. Give one or two glasses of water to drink. Refer for medical attention .

4.2 Most important symptoms/effects, acute and delayed

Exposure Routes: inhalation, ingestion, skin and/or eye contact Symptoms: Irritation eyes, skin, nose, throat; narcosis Target Organs: Eyes, skin, respiratory system, central nervous system (NIOSH, 2016)

4.3 Indication of immediate medical attention and special treatment needed, if necessary

/SRP:/ Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR if necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on the left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. /Poisons A and B/

5.Fire-fighting measures

5.1 Extinguishing media

Suitable extinguishing media

Suitable extinguishing media. For small (incipient) fires, use media such as "alcohol" foam, dry chemical, or carbon dioxide. For large fires, apply water from as far as possible. Use very large quantities (flooding) of water applied as a mist or spray; solid streams of water may be ineffective. Cool all affected containers with flooding quantities of water. Special protective equipment for fire-fighters: Wear self contained breathing apparatus for fire fighting if necessary. Further information: Use water spray to cool unopened containers.

5.2 Specific hazards arising from the chemical

This chemical is combustible.

5.3 Special protective actions for fire-fighters

Wear self-contained breathing apparatus for firefighting if necessary.

6.Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures

Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.

6.2 Environmental precautions

Personal protection: chemical protection suit including self-contained breathing apparatus. Collect leaking and spilled liquid in sealable glass or mild steel containers as far as possible. Absorb remaining liquid in dry sand or inert absorbent. Then store and dispose of according to local regulations.

6.3 Methods and materials for containment and cleaning up

ACCIDENTAL RELEASE MEASURES. Personal precautions: Wear respiratory protection. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapors accumulating to form explosive concentrations. Vapors can accumulate in low areas. Environmental precautions: Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Methods and materials for containment and cleaning up: Contain spillage, and then collect with an electrically protected vacuum cleaner or by wet-brushing and place in container for disposal according to local regulations. Keep in suitable, closed containers for disposal.

7.Handling and storage

7.1 Precautions for safe handling

Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure - obtain special instructions before use.Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.

7.2 Conditions for safe storage, including any incompatibilities

Store only if stabilized. Cool. Dry. Well closed. Ventilation along the floor. Separated from strong bases, strong acids and food and feedstuffs.Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Recommended storage temperature: 2 - 8°C Moisture sensitive. Handle and store under inert gas.

8.Exposure controls/personal protection

8.1 Control parameters

Occupational Exposure limit values

Recommended Exposure Limit: 10 Hr Time-Weighted Avg: 25 ppm (75 mg/cu m).

Biological limit values

no data available

8.2 Appropriate engineering controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

8.3 Individual protection measures, such as personal protective equipment (PPE)

Eye/face protection

Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin protection

Wear impervious clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Respiratory protection

Wear dust mask when handling large quantities.

Thermal hazards

no data available

9.Physical and chemical properties

Physical state Clear slightly viscous liquid
Colour Colorless, slightly viscous liquid
Odour no data available
Melting point/ freezing point -54oC
Boiling point or initial boiling point and boiling range 160-161oC
Flammability Class IIIA Combustible Liquid: Fl.P. at or above 60°C and below 93.33°C.Combustible.
Lower and upper explosion limit / flammability limit no data available
Flash point 71oC
Auto-ignition temperature 415°C
Decomposition temperature 166°C
pH no data available
Kinematic viscosity no data available
Solubility greater than or equal to 100 mg/mL at 17.78°C
Partition coefficient n-octanol/water (log value) log Kow = -0.95
Vapour pressure 0.9 mm Hg at 25°C ; 2.5 mm Hg at 66.11°C
Density and/or relative density 1.143
Relative vapour density 2.15 (Relative to Air)
Particle characteristics no data available

10.Stability and reactivity

10.1 Reactivity

no data available

10.2 Chemical stability

Stable under recommended storage conditions.

10.3 Possibility of hazardous reactions

GLYCIDOL is sensitive to moisture. It is also sensitive to light. It may polymerize if heated above room temperature. It may darken on storage. Stability studies of this chemical stored for two week protected from light indicated definite decomposition at 60°C, and strongly indicated instability at 25°C. A solution of this compound in water was found to be unstable when stored at room temperature, even after one day in the dark. This chemical is incompatible with strong oxidizers. It will undergo explosive decomposition in the presence of strong acids or bases, salts (such as aluminum chloride, iron(III)chloride or tin(IV) chloride) or metals (such as copper and zinc). It is also incompatible with nitrates. It will attack some forms of plastics, rubber and coatings.

10.4 Conditions to avoid

no data available

10.5 Incompatible materials

Violent reaction with strong oxidizers, nitrates. Decomposes on contact (especially in the presence of heat) with strong acids, strong bases, water, metal salts (e.g., aluminum chloride, ferric chloride, tin chloride) or metals (copper, zinc), causing fire and explosion hazard ... Attacks some plactics, rubber, and coatings.

10.6 Hazardous decomposition products

When heated to decomposition it emits acrid smoke and fumes.

11.Toxicological information

Acute toxicity

  • Oral: LD50 Rat oral 420 mg/kg
  • Inhalation: LC50 Rat inhalation 580 ppm/8 hr
  • Dermal: no data available

Skin corrosion/irritation

no data available

Serious eye damage/irritation

no data available

Respiratory or skin sensitization

no data available

Germ cell mutagenicity

no data available

Carcinogenicity

No epidemiological data relevant to the carcinogenicity of glycidol were available. There is sufficient evidence in experimental animals for the carcinogenicity of glycidol. Overall evaluation: Glycidol is probably carcinogenic to humans (Group 2A).

Reproductive toxicity

no data available

STOT-single exposure

no data available

STOT-repeated exposure

no data available

Aspiration hazard

no data available

12.Ecological information

12.1 Toxicity

  • Toxicity to fish: no data available
  • Toxicity to daphnia and other aquatic invertebrates: no data available
  • Toxicity to algae: no data available
  • Toxicity to microorganisms: no data available

12.2 Persistence and degradability

AEROBIC: Glycidol, present at 100 mg/L, reached 85% of its theoretical BOD in 4 weeks using an activated sludge inoculum at 30 mg/L in the Japanese MITI test(1). It was below the detection limit of 1 ppm after approximately 4 days at a test chemical concentration of 100 mg/L and added to an activated sludge inoculum in 250-ml Erlenmeyer shaker flasks incubated in both nutrient broth and basal salts media at 30°C. When present as the sole source of carbon present, glycidol was below the detection limit after approximately 10 days(2).

12.3 Bioaccumulative potential

An estimated BCF of 3 was calculated in fish for glycidol(SRC), using a log Kow of -0.95(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).

12.4 Mobility in soil

The Koc of glycidol is estimated as 1(SRC), using a log Kow of -0.95(1) and a regression-derived equation(2). According to a classification scheme(3), this estimated Koc value suggests that glycidol is expected to have very high mobility in soil.

12.5 Other adverse effects

no data available

13.Disposal considerations

13.1 Disposal methods

Product

The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.

Contaminated packaging

Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.

14.Transport information

14.1 UN Number

ADR/RID: UN2810 IMDG: UN2810 IATA: UN2810

14.2 UN Proper Shipping Name

ADR/RID: TOXIC LIQUID, ORGANIC, N.O.S.
IMDG: TOXIC LIQUID, ORGANIC, N.O.S.
IATA: TOXIC LIQUID, ORGANIC, N.O.S.

14.3 Transport hazard class(es)

ADR/RID: 6.1(b) IMDG: 6.1(b) IATA: 6.1(b)

14.4 Packing group, if applicable

ADR/RID: III IMDG: III IATA: III

14.5 Environmental hazards

ADR/RID: no IMDG: no IATA: no

14.6 Special precautions for user

no data available

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

no data available

15.Regulatory information

15.1 Safety, health and environmental regulations specific for the product in question

Chemical name Common names and synonyms CAS number EC number
glycidol glycidol 556-52-5 none
European Inventory of Existing Commercial Chemical Substances (EINECS) Listed.
EC Inventory Listed.
United States Toxic Substances Control Act (TSCA) Inventory Listed.
China Catalog of Hazardous chemicals 2015 Not Listed.
New Zealand Inventory of Chemicals (NZIoC) Listed.
Philippines Inventory of Chemicals and Chemical Substances (PICCS) Listed.
Vietnam National Chemical Inventory Listed.
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) Listed.

16.Other information

Information on revision

Creation Date Aug 15, 2017
Revision Date Aug 15, 2017

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

  • IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
  • HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
  • IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
  • eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
  • CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
  • ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
  • ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
  • Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
  • ECHA - European Chemicals Agency, website: https://echa.europa.eu/

Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.
Post a RFQ

Enter 15 to 2000 letters.Word count: 0 letters

Attach files(File Format: Jpeg, Jpg, Gif, Png, PDF, PPT, Zip, Rar,Word or Excel Maximum File Size: 3MB)

1

What can I do for you?
Get Best Price

Get Best Price for 556-52-5