Journal of The Electrochemical Society, 153 ͑5͒ C318-C324 ͑2006͒
C323
Figure 11. Measurement of pH as a function of time near cathode surface
during Ni electrodeposition from sulfamate electrolytes at 28°C. The curve
near the top of the plot illustrates the rapid pH rise during electrodeposition
when no boric acid is present, while the second curve at the bottom of the
figure shows the relatively small pH rise occurring when boric acid is present
Figure 12. Response of pH near the cathode surface for filtered and unfil-
tered 28°C Ni sulfamate baths ͑both with 30 g/L boric acid͒ during elec-
trodeposition at 3 mA/cm . Despite the large differences in film stress ob-
served for these deposition conditions ͑see Fig. 3͒, both filtered and
unfiltered baths exhibit similar surface pH behavior.
2
͑
both baths were filtered in this case͒.
ences in pH near the surface are observed. We thus postulate that at
low temperatures, electrolyte handling sensitivity is due to the for-
mation of polyborates.
2
8°C. The curve near the upper part of the figure is the response
from a Ni sulfamate electrolyte with no boric acid. Boric acid has
been shown to suppresses hydrogen evolution and stabilize the pH
near the cathode during Ni and Ni alloy electrodeposition.
1
7,28,30,31
Thus, when no boric acid is present, the pH rises to about 6. This pH
rise for the boric acid-free bath is consistent with previous work
Acknowledgment
The authors thank Dorrance McLean for her support with respect
to electrodeposition. Sandia is a multiprogram laboratory operated
by Sandia Corporation, a Lockheed Martin Company, for the United
States Department of Energy under contract no. DE-AC04-
with Watts solutions with no boric acid, where pH values between 5
and 7 were attained, depending on Ni2+ concentration.
16,32
The sec-
ond curve in Fig. 11 shows the pH rise associated with the filtered
2
bath at 28°C for 15 mA/cm . A fairly modest rise from 3.5 to about
9
4AL85000.
3
.8 was observed. This behavior is reasonable and in accord with
4,16
previous measurements using Watts and Ni sulfamate solutions.
Sandia National Laboratories assisted in meeting the publication costs of
Considering the measurement sensitivity shown in Fig. 11, the pH
electrode assembly is clearly capable of detecting changes in pH
near the surface if they occur.
this article.
References
1
. D. Baudrand, Met. Finish., 94͑7͒, 15 ͑1996͒.
2. J. L. Marti, Plating, 53͑1͒, 61 ͑1966͒.
. Y. Tsuru, M. Nomura, and F. R. Foulkes, J. Appl. Electrochem., 30, 231 ͑2000͒.
A summary of all pH measurements is given in Table II. Re-
2
sponse curves for depositions at 3 mA/cm using filtered and unfil-
3
tered solutions are shown in Fig. 12. These two conditions are most
interesting given the strong differences in film stress previously ob-
served in these cases. Figure 12 shows that pH changes for both
conditions are similar and fairly small, from 3.5 to about 3.6. Upon
close comparison of Tables I and II, it is apparent that the filtering-
induced changes in CE and pH are consistent; at low current densi-
ties, a slight rise in the CE and a smaller increase in pH is noted for
filtered baths, while at higher current densities, a lower CE and a
larger increase in pH is observed. Electrolyte handling does not have
a large effect on surface pH, even under conditions that lead to large
changes in film stress. This would suggest that adsorbed hydrogen
does not play a role in higher observed film stresses at low deposi-
tion rates in filtered baths. We thus attribute such changes in the
deposited material not to adsorbed hydrogen but to changes in other
adsorbates, most likely polyborates.
4. Y. Tsuru, M. Nomura, and F. R. Foulkes, J. Appl. Electrochem., 32, 629 ͑2002͒.
5. J. W. Dini and H. R. Johnson, Thin Solid Films, 54, 183 ͑1978͒.
6
7
8
. J. L. Marti and G. P. Lanza, Plating, 56͑4͒, 377 ͑1969͒.
. J. W. Dini and H. R. Johnson, Surf. Technol., 4, 217 ͑1976͒.
. B. E. Jacobson and J. W. Sliwa, Plat. Surf. Finish., 66͑9͒, 42 ͑1979͒.
9. T. E. Buchheit, D. A. LaVan, J. R. Michael, T. R. Christenson, and S. D. Leith,
Metall. Mater. Trans. A, 33, 539 ͑2002͒.
0. W. H. Safranek, The Properties of Electrodeposited Metals and Alloys, 2nd ed.,
American Electroplaters and Surface Finishers Society, U. S. A. ͑1986͒.
1
11. J. W. Dini, Electrodeposition: The Materials Science of Coatings and Substrates,
Noyes Publications, Norwich ͑1993͒.
12. C.-S. Lin, K.-C. Peng, P.-C. Hsu, L. Chang, and C.-H. Chen, Mater. Trans., JIM,
4
1͑7͒, 777 ͑2000͒.
1
1
3. J. W. Dini and H. R. Johnson, Thin Solid Films, 54, 183 ͑1978͒.
4. A. Ruzzu and B. Matthis, Microsyst. Technol., 8 116 ͑2002͒.
15. J. J. Kelly, N. Yang, T. Headley, and J. Hachman, J. Electrochem. Soc., 150, C445
͑2003͒.
1
6. J. Ji, W. C. Cooper, D. B. Dreisinger, and E. Peters, J. Appl. Electrochem., 25, 642
1995͒.
͑
1
1
7. H. Deligianni and L. T. Romankiw, IBM J. Res. Dev., 37͑2͒, 85 ͑1993͒.
8. P. Kern, C. Bonhote, and L. T. Romankiw, in Magnetic Materials, Processes, and
Devices VII and Electrodeposition of Alloys, S. Krongelb, L. T. Romankiw, J.-W.
Chang, Y. Kitamoto, J. W. Judy, C. Bonhote, G. Zangari, and W. Schwarzacher,
Editors, PV 2002-27, p. 328, The Electrochemical Society Proceedings Series,
Pennington, NJ ͑2003͒.
Conclusions
We have shown that at low electrolyte temperatures, boric acid
acts as an inhibitor if the electrolyte is handled in such a way as to
promote the formation of polyborates. Particle filtering of electro-
lytes thus becomes an important consideration at low bath tempera-
tures. Higher film stresses are observed at low current densities
Ͻ5 mA/cm ͒ in low-temperature, filtered baths. Despite the large
changes in film stress for these conditions, no concomitant differ-
19. S. A. Watson, Nickel Sulphamate Solutions, NiDI Technical Series 10052, Nickel
Development Institute, Toronto ͑1989͒.
2
2
0. N. V. Mandich and D. W. Baudrand, Plat. Surf. Finish., 89͑9͒, 68 ͑2002͒.
1. J. L. Bubendorff, L. Cagnon, V. Costa-Kieling, J. P. Bucher, and P. Allongue, Surf.
Sci., 384, L836 ͑1997͒.
2
͑