- Differential Pressure Transmitter STK337
-
Specifications of Differential Pressure Transmitter STK337:
.jpg)
1. Measuring range
From -7.5...7.5Kpa to -7000...7000Kpa
Maximum range turndown 100:1
Min. operating pressure: 0.12Kpa
Static pressure: 30bar...130bar2. Area of Application
Process control
Chemical industry3. Technical Data
Accuracy:0.075 %
Intrinsic safety: ExiaCT4CT6
Supply: 10.5-45VDC
Output: 420mA with superimposed digital communication signal for HART protocol
Environment: -30+80
Long term stability: 0.1%/year
Static pressure effect: <0.005% of URL/1V
Power supply effect: <0.01% of URL/g when tested 200Hz in any axis relative
Vibration effect: Zero shift which can be calibrated out, no span effect
Ingress Protection:IP65
Prev: Portable Ceramic Tube X-ray Machine
Next: Linear Bush Series (LME-AJ) - 【Back】【Close 】【Print】【Add to favorite 】
- Related information
- Suitable Foods Deal with High Pressure for You
- Gay-Lussac's law
- AV-PL Constant Pressure Filler
- ZNG and ZN Series Vacuum Pressure-reduced Concentration Can
- DuPont 900 Differential Thermal Analyzer
- High Pressure Reactor KH
- High Pressure Reactor KH
- Seismic Restrain Electric Contact Pressure Gauge
- Special Pressure Gauge
- Digital Pressure Gauge
-
Health and Chemical more >
-
Hot Products
- 20169-45-3 9H-thioxanthen-9-one oxime
- 68425-37-6 Alcohols, coco
- 372-09-8 Cyanoacetic acid
- 187393-00-6 BIS-ETHYLHEXYLOXYPHENOL METHOXYPHENYL TRIAZINE
- 67829-13-4 2-(Phosphonooxy)propane-1,3-diyl bismethacrylate
- 41556-26-7 Bis(1,2,2,6,6-pentamethyl-4-piperidyl) sebacate
- 16009-13-5 Hemin
- 1338-51-8 Benzenesulfonamide, ar-methyl-, reaction products with formaldehyde
- 66317-91-7 CALCIUM COPPER(II) EDTA 2-HYDRATE
- 9006-26-2 ETHYLENE MALEIC ANHYDRIDE CO-POLYMER
- 61276-17-3 Verbascoside
- 171596-29-5 Tadalafil