The early bactericidal activity of rifabutin measured by sputum viable counts in Hong Kong patients with pulmonary tuberculosis
-
Add time:07/24/2019 Source:sciencedirect.com
Previously untreated patients with smear-positive pulmonary tuberculosis were randomly allocated to treatment with 600, 300, 150 or 75 mg doses of rifabutin (LM427, ansamycin), 600, 300 or 150 mg of rifampicin, 300 mg isoniazid or to no drug daily for 2 days. The fall in viable counts of Mycobacterium tuberculosis in sputum collections during the 2 days, termed the early bactericidal activity (EBA), was estimated from counts of colony-forming units (cfu) on selective 7H-11 agar medium. The EBA for rifabutin ranged from −0.039 (an increase in counts) to 0.049 log10 cfu/ml/day whereas the EBA increased from 0.071 for 150 mg rifampicin to 0.293 log10 cfu/ml/day for 600 mg rifampicin and was 0.43 log10 cfu/ml/day for 300 mg isoniazid. The difference between the EBAs for rifabutin and rifampicin just attained significance (P = 0.05) suggesting that rifabutin was inactive or less active than rifampicin against the extracellular bacilli in pulmonary cavities. Peak plasma concentrations of rifabutin after the initial doses were found to be proportional to dose size and were approximately 7 times lower than those after the same dose size of rifampicin. The lower EBA of rifabutin as compared to rifampicin is probably due to the low plasma concentrations which are not fully compensated for by slightly greater antituberculosis activity of rifabutin in vitro.
We also recommend Trading Suppliers and Manufacturers of 25-DESACETYL RIFABUTIN (cas 100324-63-8). Pls Click Website Link as below: cas 100324-63-8 suppliers
Prev:Specific high-performance liquid chromatography assay for determination of rifabutin plasma concentration following Extrelut column extraction
Next:Determination of oxpentifylline and a metabolite, 1-(5′-hydroxyhexyl)-3,7-dimethylxanthine, by gas—liquid chromatography using a nitrogen-selective detector) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Specific high-performance liquid chromatography assay for determination of rifabutin plasma concentration following Extrelut column extraction07/23/2019
- Determination of rifabutin in human plasma by high-performance liquid chromatography with ultraviolet detection07/22/2019
- Rifampin, but not rifabutin, may produce opiate withdrawal in buprenorphine-maintained patients07/20/2019
- Determination of the rifamycin antibiotics rifabutin, rifampin, rifapentine and their major metabolites in human plasma via simultaneous extraction coupled with LC/MS/MS07/21/2019
- Identification of rat urinary metabolites of rifabutin using LC–MSn and LC–HR-MS07/19/2019


