Internal concentrations of perfluorobutane sulfonate (PFBS) comparable to those of perfluorooctane sulfonate (PFOS) induce reproductive toxicity in Caenorhabditis elegans
-
Add time:07/24/2019 Source:sciencedirect.com
Perfluorobutane sulfonate (PFBS) is considered a less-toxic replacement for perfluorooctane sulfonate (PFOS), with multiple applications in industrial and consumer products. Previous studies comparing their toxicity generally used similar exposure levels, without taking internal concentrations into account. The current study compared the reproductive toxicity of PFOS and PFBS, at similar internal concentrations, to Caenorhabditis elegans (C. elegans). PFBS was much less bioaccumulative than PFOS. The 48-h median lethal concentrations (LC50) for PFOS and PFBS were 1.4 μM (95% confidence interval [CI]: 1.1–1.6) and 794 μM (95% CI: 624–1009), respectively. Egg production and brood number of C. elegans decreased markedly following exposure to 0.1 μM PFOS or 1000 or 1500 μM PFBS. Germ-cell apoptosis and production of reactive oxygen species increased significantly following exposure to 2 μM PFOS or 500 or 1000 μM PFBS. Expression of the antioxidant genes sod-3, ctl-2, and gst-4 and the pro-apoptotic genes egl-1 and ced-13 was altered significantly following PFOS and PFBS exposure. These findings indicate that both chemicals exert reproductive toxicity in C. elegans, probably owing to germ-cell apoptosis resulting from elevated levels of reactive oxygen species. The vastly different exposure concentrations of PFBS and PFOS used in this study produced similar internal concentrations, leading to the reproductive toxicities observed.
We also recommend Trading Suppliers and Manufacturers of glutathione sulfonate (cas 1637-70-3). Pls Click Website Link as below: cas 1637-70-3 suppliers
Prev:Butyrylcholinesterase inhibited by nerve agents is efficiently reactivated with chlorinated pyridinium oximes
Next:Picomole analysis of glutathione, glutathione disulfide, glutathione S-sulfonate, and cysteine S-sulfonate by high-performance liquid chromatography) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Microwave-assisted derivatization combined with coacervative extraction for determining glutathione in biomatrix samples, followed by capillary liquid chromatography07/28/2019
- Three-dimensional structure of Escherichia coli glutathione S-transferase complexed with glutathione sulfonate (cas 1637-70-3): catalytic roles of Cys10 and His106107/27/2019
- Effects of sulfite on glutathione S-sulfonate and the glutathione status of lung cells07/26/2019
- Picomole analysis of glutathione, glutathione disulfide, glutathione S-sulfonate, and cysteine S-sulfonate by high-performance liquid chromatography07/25/2019


