Metabolites of phosphate flame retardants and alternative plasticizers in urine from intensive care patients
-
Add time:08/07/2019 Source:sciencedirect.com
Several regulatory offices called for the phase-out of di (2-ethylhexyl) phthalate (DEHP) in medical devices if safer alternatives are available. In medical devices, the occurrence of alternative plasticizers (APs) is widely variable among types of devices. However, plasticizer use is constantly evolving, as there is no reference to guide manufacturers in the choice and amount to be integrated into their products. As intensive care unit (ICU) patients need numerous indwelling plastic devices during their treatment, we hypothesized that these patients are exposed to APs and phosphate flame retardants and plasticizers (PFRs). Urinary metabolites of APs and PFRs were analyzed in the urine of adult ICU patients (n = 24) over a time period of four days. Our results show that adult ICU patients are exposed to PFRs as well as to APs concentrations were much lower compared to the levels of DEHP metabolites in the same samples. However, significantly higher than in controls (n = 15) this exposure resulted in detectable urinary levels in almost every patient and at every studied time point. Increasing temporal trends were observed for several metabolites from admission until day 3 at ICU. The use of specific medical devices, such as continuous venovenous hemofiltration (CVVH) and extracorporeal membrane oxygenation (ECMO), was associated with an increase in urinary concentrations for several PFR metabolites, despite the lack of information on the presence of these plasticizer chemicals in such medical devices. Further research into the possibly toxic effects of these chemicals released from medical devices is urgently needed.
We also recommend Trading Suppliers and Manufacturers of bis(2-ethylhexyl) phenyl phosphate (cas 16368-97-1). Pls Click Website Link as below: cas 16368-97-1 suppliers
Prev:Tris(2-ethylhexyl)phosphine oxide as an effective solvent mediator for constructing a serotonin-selective membrane electrode
Next:Urinary biomarkers for assessment of human exposure to monomeric aryl phosphate flame retardants) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Separation of scandium(III) and yttrium(III) by tris(2-ethylhexyl)phosphate (TEHP)08/09/2019
- Urinary biomarkers for assessment of human exposure to monomeric aryl phosphate flame retardants08/08/2019
- Tris(2-ethylhexyl)phosphine oxide as an effective solvent mediator for constructing a serotonin-selective membrane electrode08/06/2019
- Poly(vinyl chloride) membrane electrode for a stimulant, phentermine, using tris(2-ethylhexyl) phosphate as a solvent mediator08/05/2019
- Extraction and separation of uranium (IV) and certain light lanthanides from concentrated phosphoric acid solutions using octyl phenyl acid phosphate08/04/2019
- Effect of room temperature ionic liquid on the extraction behavior of Plutonium (IV) using a novel reagent, bis-(2-ethylhexyl) carbamoyl methoxy phenoxy-bis-(2-ethylhexyl) acetamide [Benzodioxodiamide, BenzoDODA]08/03/2019
-
Health and Chemical more >
-
Related Products
- Bis(2-ethylhexyl) (2H4)benzene-1,2-dicarboxylate
- Bis(2-ethylhexyl) adipate
- Bis(2-ethylhexyl) azelate
- bis(2-ethylhexyl) cyclohexane-1,2-dicarboxylate
- BIS(2-ETHYLHEXYL) ISOPHTHALATE
- BIS(2-ETHYLHEXYL) MALEATE
- Bis(2-ethylhexyl) phenyl phosphate
- Bis(2-ethylhexyl) phosphate
- Bis(2-ethylhexyl) phosphite
- Phenyl (1-piperidinocyclohexyl) ketone