Germanium dioxide as internal standard for simplified trace determination of bromate, bromide, iodate and iodide by on-line coupling ion chromatography-inductively coupled plasma mass spectrometry
-
Add time:08/12/2019 Source:sciencedirect.com
The use of elemental mass spectrometry as detection for ion chromatography allows sensitive determination of several bromine and iodine species at a reasonable time scale. Lowest concentrations observable are 66 ng L−1 for bromate, 45 ng L−1 for iodate, 74 ng L−1 for bromide and 151 ng L−1 for iodide. A major drawback of previous IC–ICP–MS applications is the high consumption of time and thus the running costs. The use of GeO2 as internal standard not only allows improved external calibration, but also semiquantitative determination of bromate, bromide, iodate and iodide without any calibration procedure. Furthermore, GeO2 can be used for all known types of anion exchange columns regardless of their construction principles. It is shown, that the analyte-to-GeO2 ratio of four bromine and iodine species was nearly constant over 4 months and almost independent from the ICP–MS instrumental settings. The quantification by means of the analyte-to-GeO2 ratio for samples taken from a bromate round robin test shows that the values obtained are in excellent agreement with calibration curve and isotope dilution results.
We also recommend Trading Suppliers and Manufacturers of NICKEL BROMATE (cas 13462-88-9). Pls Click Website Link as below: cas 13462-88-9 suppliers
Prev:Catalytic adsorptive stripping voltammetry of Co(II)-dioxime-bromate systems at renewable amalgam film electrode
Next:Electrochemical oscillations on the stationary mercury electrode in bromate solutions) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Electrochemical oscillations on the stationary mercury electrode in bromate solutions08/13/2019
- Catalytic adsorptive stripping voltammetry of Co(II)-dioxime-bromate systems at renewable amalgam film electrode08/11/2019
- Simultaneous spectrophotometric determination of iodate and bromate in water samples by the method of mean centering of ratio kinetic profiles08/10/2019
- Efficient reduction of bromates using carbon nanofibre supported catalysts: Experimental and a comparative life cycle assessment study08/09/2019
- Effects of copper and palladium on the reduction of bromate by Fe(0)08/08/2019
- Chlorination of bromide-containing waters: Enhanced bromate formation in the presence of synthetic metal oxides and deposits formed in drinking water distribution systems08/07/2019
- Catalytic reduction of bromate over monometallic catalysts on different powder and structured supports08/06/2019
- Advances in bromate reduction by heterogeneous photocatalysis: The use of a static mixer as photocatalyst support08/05/2019
-
Health and Chemical more >
-
Related Products
- Nickel (2+) sulfate
- Nickel 2 - Ethylhexanoate
- Nickel acetylacetonate
- NICKEL ALLOY, BASE, Ni 57–62, Fe 22–28, Cr 14–18, Si 0.8–1.6, Mn 0–1, C 0–0.2
- Nickel alloy, Ni,Be
- Nickel ammonium sulfate (2:2:3)
- Nickel ammonium sulfate hexahydrate
- Nickel arsenide
- Nickel arsenide sulfide
- Nickel bis(dimethyldithiocarbamate)