Thermodynamic analysis of low GWP alternatives to HFC-245fa in high-temperature heat pumps: HCFO-1224yd(Z), HCFO-1233zd(E) and HFO-1336mzz(Z)
-
Add time:08/12/2019 Source:sciencedirect.com
This paper analyses the feasibility of HCFO-1224yd(Z), HCFO-1233zd(E) and HFO-1336mzz(Z), three low global warming potential (GWP) refrigerants, as alternatives to HFC-245fa in high-temperature heat pump (HTHP) systems for low-grade waste heat recovery. HTHPs are a sustainable technology that can help to mitigate climate change through the thermal valorisation of the industrial low-grade waste heat. Before presenting and analysing the results, mapping of the minimum superheat degree requirement in the operating range, and the influence of the Internal Heat Exchanger (IHX) on each alternative are studied. The simulations were carried out at condensing temperatures from 115 to 145 °C and evaporating temperatures from 45 to 75 °C, using a single-stage cycle with and without IHX. Finally, the Total Equivalent Warming Impact (TEWI) evaluation is performed to illustrate the environmental effect of each alternative. Attending to the results, HCFO-1233zd(E) improves the COP about 27% compared to HFC-245fa, whereas HFO-1336mzz(Z) and HCFO-1224yd(Z) show an improvement of approx. 21 and 17%, respectively. Although HCFO-1233zd(E) and HCFO-1224yd(Z) present similar suction volumetric flow rate to HFC-245fa, HFO-1336mzz(Z) shows a relative increment up to 80%, and therefore, higher compressor and installation size are expected for this refrigerant. Finally, the TEWI analysis presents a significant reduction of the equivalent CO2 emissions for each low GWP alternative, between 59 and 61%. HCFO-1233zd(E) shows the highest reduction in all the simulation cases, followed by HCFO-1224yd(Z) and HFO-1336mzz(Z).
We also recommend Trading Suppliers and Manufacturers of (E,Z)-2,13-OCTADECADIENOL (cas 123551-47-3). Pls Click Website Link as below: cas 123551-47-3 suppliers
Prev:Far UV peaks contribute for identification of carotenoids E/Z isomers
Next:Construction of Z-scheme Fe2O3@e-HNbWO6 composite and its enhanced photocatalytic activity) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Synthesis of new fluorinated synthons: (E and Z) ClFCCFI and (E and Z) BrFCCFI08/15/2019
- Roles of Polycomb group proteins Enhancer of zeste (E(z)) and Polycomb (Pc) during metamorphosis and larval leg regeneration in the flour beetle Tribolium castaneum08/14/2019
- Construction of Z-scheme Fe2O3@e-HNbWO6 composite and its enhanced photocatalytic activity08/13/2019
- Far UV peaks contribute for identification of carotenoids E/Z isomers08/11/2019
- Combined experimental and theoretical study of the novel ferrocene derivatives and examining the effect of E-Z stereoisomerism on their optical properties08/10/2019
- Simultaneous experimental comparison of low-GWP refrigerants as drop-in replacements to R245fa for Organic Rankine cycle application: R1234ze(Z), R1233zd(E), and R1336mzz(E)08/09/2019
- The role of distance between donor and acceptor in configuration stability of Z/E isomers based on cyanostilbene08/08/2019
- 15N, 13C and 1H NMR study of tautomerism and E/Z isomerism in 3-[(Z)-(2-phenylhydrazinylidene)methyl]quinoxalin-2(1H)-one and 3-[(E)-(2-phenylhydrazinylidene)methyl]quinoxalin-2(1H)-one08/07/2019
- Boiling of the new low-GWP refrigerants R1234ze(Z) and R1233zd(E) inside a small commercial brazed plate heat exchanger08/06/2019