Measurements of Intracellular Mg2+ Concentration in Mouse Skeletal Muscle Fibers with the Fluorescent Indicator Mag-Indo-1
-
Add time:07/13/2019 Source:sciencedirect.com
Measurements of intracellular free magnesium concentration ([Mg2+]i) were performed on enzymatically isolated skeletal muscle fibers from mice, using the fluorescent ratiometric indicator mag-indo-1. An original procedure was developed to calibrate the dye response within the fibers: fibers were first permeabilized with saponin in the presence of a given extracellular magnesium concentration and were then embedded in silicone grease. The dye was then pressure microinjected into the saponin-permeabilized silicone-embedded fibers, and fluorescence was measured. The results show that for all tested [Mg2+], the value of the measured fluorescence ratio was higher than that found in aqueous solutions. Furthermore, the apparent binding curve that could be fit to the in vivo ratio data was shifted toward higher [Mg2+] by a factor of ∼2. Using the in vivo calibration parameters, the mean resting [Mg2+]i was found to be 1.53 ± 0.16 mM (n = 7). In an attempt to gain insight into the myoplasmic magnesium buffering capacity, we measured, together with mag-indo-1 fluorescence, the current elicited by the application of carbamylcholine (CCh) to the endplate of isolated fibers, in the presence of a high extracellular magnesium concentration. The results show that, under these conditions, a change in [Mg2+]i displaying a time course and amplitude qualitatively consistent with the CCh-induced inward current can be measured.
We also recommend Trading Suppliers and Manufacturers of MAG-INDO 1-AM (cas 130926-94-2). Pls Click Website Link as below: cas 130926-94-2 suppliers
Prev:Interaction of a protein, BSA, and a fluorescent probe, Mag-Indo-1, influence of EDTA and calcium on the equilibrium
Next:Measurement of Intracellular Magnesium Concentration in 3T3 Fibroblasts with the Fluorescent Indicator Mag-indo-1) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- High cytoplasmic Ca2+ levels reached during Ca2+-induced Ca2+ release in single smooth muscle cell as reported by a low affinity Ca2+ indicator Mag-Indo-107/16/2019
- Are histidine rings the main potential sites of the interaction between proteins and the fluorescent Mg2+ indicator Mag-indo l?07/15/2019
- Measurement of Intracellular Magnesium Concentration in 3T3 Fibroblasts with the Fluorescent Indicator Mag-indo-107/14/2019
- Interaction of a protein, BSA, and a fluorescent probe, Mag-Indo-1, influence of EDTA and calcium on the equilibrium07/12/2019


