Improvements of COBRA-TF on the effect of flow blockage during a LB LOCA with consideration of fuel relocation phenomenon
-
Add time:08/17/2019 Source:sciencedirect.com
Coolability of the partially blocked core in a large break loss-of-coolant accident (LB LOCA) is one of the most important thermal-hydraulic concerns for nuclear reactor safety analysis. During blowdown phase and early stage of reflooding phase in the LB LOCA, the prevailing wall-to-vapor convective heat transfer plays an important role on the decay heat removal process. Experiments on single-phase convective heat transfer to vapor were conducted in 5 × 5 heater rod bundles containing 3 × 3 ballooned rods of 90% flow blockage ratio with consideration of fuel relocation phenomenon. The obtained experimental data were used to assess the single-phase heat transfer enhancement models of the COBRA-TF code. The assessment results showed underprediction of local heat transfer downstream of the flow blockage. Therefore, a new correlation has been proposed to improve the prediction capability of the conventional models by more accurately describing the flow blockage effect. The new correlation predicted the local heat transfer satisfactorily within a 20% discrepancy of the experimental data for various kinds of flow blockage configurations.
We also recommend Trading Suppliers and Manufacturers of TF-A (cas 134965-85-8). Pls Click Website Link as below: cas 134965-85-8 suppliers
Prev:Performance analysis of a graded winding pack design for the EU DEMO TF coil in normal and off-normal conditions
Next:Structure–activity relationship of Phosmidosine (cas 134966-01-1): importance of the 7,8-dihydro-8-oxoadenosine residue for antitumor activity) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Performance analysis of a graded winding pack design for the EU DEMO TF coil in normal and off-normal conditions08/16/2019
- Abiotic stress induced miRNA-TF-gene regulatory network: A structural perspective08/15/2019
- A new sample treatment for asialo-Tf determination with capillary electrophoresis: an added value to the analysis of CDT08/14/2019
- Capillary Electrophoresis (CE) vs. HPLC in the determination of asialo-Tf, a crucial marker for the reliable interpretation of questioned CDT increases08/13/2019
- Detailed structural analysis of a graded TF coil winding pack for EU DEMO08/12/2019
- Stress2TF: a manually curated database of TF regulation in plant response to stress08/11/2019
- A novel variant m.641A>T in the mitochondrial MT-TF gene is associated with epileptic encephalopathy in adolescent08/10/2019
- A method for gene essentiality in miRNA-TF-mRNA co-regulatory network and its application on prostate cancer08/09/2019
- Cluster binding studies with two anti-Thomsen-Friedenreich (anti-core-1, CD176, TF) antibodies: Evidence for a multiple TF epitope08/08/2019