Fluoride removal from water by electrocoagulation: Effect of the type of water and the experimental parameters
-
Add time:07/15/2019 Source:sciencedirect.com
Contamination of the ground water with fluoride is a great problem worldwide. Removal of fluoride (F−) ions from simulated natural waters containing fluoride by electrocoagulation (EC) using aluminum electrodes, has been investigated in a discontinuous lab cell. Two types of water have been studied: local tap water and deionized water-based luoride solutions of sodium fluoride with addition of sodium chloride to reach the desired conductivity. The effect of four operating parameters has been followed for a current density fixed at 5 mA/cm2 within the following ranges: fluoride concentration (5–50 mg/L), temperature (25–55 °C), conductivity (1–6 mS/cm) and initial pH (4–8.5). In accordance with published data, the presence of 61 mg/L buffering hydrogencarbonate ions in the tap water was found to substantially reduce the Al(III) amount required for a given abatement in comparison with deionized water. Performance comparison of the discontinuous electrocoagulation treatment between the two types of water has been discussed for 90% abatement of F− introduced, in terms of the amount of Al(III) dissolved over the initial fluoride concentration, the parameters of a previous adsorption model and the fraction of Al(III) flocs not involved in the adsorption. EC performances were shown to be governed by the solution pH for the two types of water, with little effect of the other operating conditions: at initial pH 6, F− abatement was found to require two or three times less trivalent aluminium than at initial pH 8.5.
We also recommend Trading Suppliers and Manufacturers of Aluminium(I)fluoride (cas 13595-82-9). Pls Click Website Link as below: cas 13595-82-9 suppliers
Prev:Nickel fluoride as a surface activation agent for electroless nickel coating of anodized AA1050 aluminum alloy
Next:Towards the implementation of an ion-exchange system for recovery of fluoride commodity chemicals. Kinetic and dynamic studies) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Towards the implementation of an ion-exchange system for recovery of fluoride commodity chemicals. Kinetic and dynamic studies07/16/2019
- Nickel fluoride as a surface activation agent for electroless nickel coating of anodized AA1050 aluminum alloy07/14/2019
- Fluorides decontamination by means of Aluminum polychloride based commercial coagulant07/13/2019
- Preparation and characterization of novel green synthesized iron–aluminum nanocomposite and studying its efficiency in fluoride removal07/12/2019
- Enhancing ignition and combustion characteristics of micron-sized aluminum powder in steam by adding sodium fluoride07/11/2019