A comparison of recent parametric neuroreceptor mapping approaches based on measurements with the high affinity PET radioligands [11C]FLB 457 (cas 107188-66-9) and [11C]WAY 100635
-
Add time:08/20/2019 Source:sciencedirect.com
In positron emission tomography (PET) studies, the detailed mapping of neuroreceptor binding is a trade-off between parametric accuracy and spatial precision. Logan's graphical approach is a straightforward way to quickly obtain binding potential values at the voxel level but it has been shown to have a noise-dependent negative bias. More recently suggested approaches claim to improve parametric accuracy with retained spatial resolution. In the present study, we used PET measurements on regional D2 dopamine and 5-HT1A serotonin receptor binding in man to compare binding potential (BP) estimates of six different parametric imaging approaches to the traditional Logan ROI-based approach which was used as a “gold standard”. The parametric imaging approaches included Logan's reference tissue graphical analysis (PILogan), its version recently modified by Varga and Szabo (PIVarga), two versions of the wavelet-based approach, Gunn's basis function method (BFM) and Gunn et al.'s recent compartmental theory-based approach employing basis pursuit strategy for kinetic modeling (called DEPICT). Applicability for practical purposes in basic and clinical research was also considered. The results indicate that the PILogan and PIVarga approaches fail to recover the correct values, the wavelet-based approaches overcome the noise susceptibility of the Logan fit with generally good recovery of BP values, and BFM and DEPICT seem to produce values with a bias dependent on receptor density. Further investigations on this bias and other phenomena revealed fundamental issues regarding the use of BFM and DEPICT on noisy voxel-wise data. In conclusion, the wavelet-based approaches seem to provide the most valid and reliable estimates across regions with a wide range of receptor densities. Furthermore, the results support the use of receptor parametric imaging in applied studies in basic or clinical research.
We also recommend Trading Suppliers and Manufacturers of FLB 457 (cas 107188-66-9). Pls Click Website Link as below: cas 107188-66-9 suppliers
Prev:Regular ArticleError Analysis for Quantification of [11C]FLB 457 (cas 107188-66-9) Binding to Extrastriatal D2 Dopamine Receptors in the Human Brain
Next:[11C]Cyclopropyl-FLB 457 (cas 107188-66-9): A PET radioligand for low densities of dopamine D2 receptors) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- [11C]Cyclopropyl-FLB 457 (cas 107188-66-9): A PET radioligand for low densities of dopamine D2 receptors08/21/2019
- Regular ArticleError Analysis for Quantification of [11C]FLB 457 (cas 107188-66-9) Binding to Extrastriatal D2 Dopamine Receptors in the Human Brain08/19/2019
- Regular ArticlePET Mapping of Extrastriatal D2-like Dopamine Receptors in the Human Brain Using an Anatomic Standardization Technique and [11C]FLB 457 (cas 107188-66-9)08/18/2019
- Original articlePreparation of [76Br]FLB 457 (cas 107188-66-9) and [76Br]FLB 463 for examination of striatal and extrastriatal dopamine D-2 receptors with PET08/17/2019
- Increased dopamine release in the right anterior cingulate cortex during the performance of a sorting task: A [11C]FLB 457 (cas 107188-66-9) PET study08/16/2019
- Extrastriatal dopaminergic abnormalities of DA homeostasis in Parkinson's patients with medication-induced pathological gambling: A [11C] FLB-457 and PET study08/15/2019
- Research reportExtrastriatal D2 and striatal D2 receptors in depressive illness: Pilot PET studies using [11C]FLB 457 (cas 107188-66-9) and [11C]raclopride08/14/2019
- Error analysis for PET measurement of dopamine D2 receptor occupancy by antipsychotics with [11C]raclopride and [11C]FLB 457 (cas 107188-66-9)08/13/2019
- Biodistribution and radiation dosimetry in humans of [11C]FLB 457 (cas 107188-66-9), a positron emission tomography ligand for the extrastriatal dopamine D2 receptor☆08/12/2019