A calixarene-based ion-selective electrode for thallium(I) detection
-
Add time:08/19/2019 Source:sciencedirect.com
Three new calixarene Tl+ ionophores have been utilized in Tl+ ion-selective electrodes (ISEs) yielding Nernstian response in the concentration range of 10−2–10−6 M TlNO3 with a non-optimized filling solution in a conventional liquid contact ISE configuration. The complex formation constants (log βIL) for two of the calixarene derivatives with thallium(I) (i.e. 6.44 and 5.85) were measured using the sandwich membrane technique, with the other ionophore immeasurable due to eventual precipitation of the ionophore during these long-term experiments. Furthermore, the unbiased selectivity coefficients for these ionophores displayed excellent selectivity against Zn2+, Ca2+, Ba2+, Cu2+, Cd2+ and Al3+ with moderate selectivity against Pb2+, Li+, Na+, H+, K+, NH4+ and Cs+, noting that silver was the only significant interferent with these calixarene-based ionophores. When optimizing the filling solution in a liquid contact ISE, it was possible to achieve a lower limit of detection of approximately 8 nM according to the IUPAC definition. Last, the new ionophores were also evaluated in four solid-contact (SC) designs leading to Nernstian response, with the best response noted with a SC electrode utilizing a gold substrate, a poly(3-octylthiophene) (POT) ion-to-electron transducer and a poly(methyl methacrylate)–poly(decyl methacrylate) (PMMA–PDMA) co-polymer membrane. This electrode exhibited a slope of 58.4 mV decade−1 and a lower detection limit of 30.2 nM. Due to the presence of an undesirable water layer and/or leaching of redox mediator from the graphite redox buffered SC, a coated wire electrode on gold and graphite redox buffered SC yielded grossly inferior detection limits against the polypyrrole/PVC SC and POT/PMMA–PDMA SC ISEs that did not display signs of a water layer or leaching of SC ingredients into the membrane.
We also recommend Trading Suppliers and Manufacturers of THALLIUM(I)HYDROXIDE (cas 1310-83-4). Pls Click Website Link as below: cas 1310-83-4 suppliers
Prev:Integrated three-electrode screen-printed sensor modified with bismuth film for voltammetric determination of thallium(I) at the ultratrace level
Next:Regular ArticleThermodynamic properties of thallium(I) hydroxide in the vapor state) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Synthesis and application of a novel nanostructured ion-imprinted polymer for the preconcentration and determination of thallium(I) ions in water samples08/21/2019
- Regular ArticleThermodynamic properties of thallium(I) hydroxide in the vapor state08/20/2019
- Integrated three-electrode screen-printed sensor modified with bismuth film for voltammetric determination of thallium(I) at the ultratrace level08/18/2019
- Thallium concentration and thallium isotope composition of lateritic terrains08/17/2019
- Preparation of thallium nanomaterials from thallium(I) coordination polymers precursors synthesized by green sonochemical and mechanochemical processes08/16/2019
- Superior adsorption of thallium(I) on titanium peroxide: Performance and mechanism08/15/2019