Progress in cardiologyDynamic planar myocardial perfusion imaging in patients with one-vessel disease with intracoronary injection of technetium 99m teboroxime during papaverine-induced coronary hyperemia
-
Add time:08/20/2019 Source:sciencedirect.com
This study examined the imaging results and kinetics of technetium 99m teboroxime after its intracoronary injection during papaverine-induced coronary hyperemia in patients with one-vessel disease before and after coronary angioplasty. Thirteen patients with ≥90% diameter stenosis of either the left anterior descending or the left circumflex coronary artery were included. Two patients were excluded because of ventricular tachycardia during papaverine injection in one patient and unsuccessful angioplasty in the second patient. One mCi of technetium 99m teboroxime was injected into the left main coronary artery during coronary hyperemia induced by intracoronary injection of papaverine. Dynamic acquisition in a frame mode (20 sec/frame) was performed for 5 minutes in the left anterior oblique projection with a multicrystal gamma camera before and after successful angioplasty. Ischemic:normal count ratio increased from 0.75 ± 0.4 before to 1.00 ± 0.50 after angioplasty (p < 0.1). The T12 of teboroxime was 6.5 ± 1.5 min in the normal zone and 7.2 ± 1.9 min in the ischemic zone (p, NS). Perfusion defects were visible in the territory of the stenosed coronary artery in 9 of 11 patients before angioplasty and in 7 of 11 patients after angioplasty. The image quality was excellent in all studies. Thus this study shows that performing dynamic imaging with intracoronary injection of technetium 99m teboroxime is feasible. This technique may be useful to study the impact of angioplasty on coronary flow and tracer kinetics.
We also recommend Trading Suppliers and Manufacturers of TECHNETIUM TEBOROXIME (cas 100995-86-6). Pls Click Website Link as below: cas 100995-86-6 suppliers
Prev:The Canadian exercise technetium 99m-labeled teboroxime single-photon emission computed tomographic study+
Next:MethodTomographic myocardial perfusion imaging with technetium-99m teboroxime during adenosine-induced coronary hyperemia: Correlation with thallium-201 imaging☆) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Comparison between technetium-99m-teboroxime and thallium-201 dipyridamole planar myocardial perfusion imaging in detection of coronary artery disease08/23/2019
- Experimental studyMyocardial kinetics of technetium-99m teboroxime in the presence of postischemic injury, necrosis and low flow reperfusion08/22/2019
- MethodTomographic myocardial perfusion imaging with technetium-99m teboroxime during adenosine-induced coronary hyperemia: Correlation with thallium-201 imaging☆08/21/2019
- The Canadian exercise technetium 99m-labeled teboroxime single-photon emission computed tomographic study+08/19/2019
- Technetium-99m teboroxime regional myocardial washout in subjects with and without coronary artery disease☆08/18/2019
- Experimental studyThe relationship between myocardial retention of technetium-99m teboroxime and myocardial blood flow☆08/17/2019
- Clinical experience with technetium 99m teboroxime08/16/2019


