Lipophilicity measurement of nicotinates by reversed-phase high-performance liquid chromatography : Differences in retention behaviour, but similarities of log kw values, in methanol-water and acetonitrile-water eluents
-
Add time:08/17/2019 Source:sciencedirect.com
The lipophilicity of 22 nicotinate esters was examined by reversed-phase high-performance liquid chromatography using methanol-water and acetonitrile-water as eluents. In the former system, a linear relationship exists between the log of the capacity factor (log k) and the fraction of modifier in the eluent. In contrast, the relationship is parabolic in the acetonitrile-water system. This behaviour is interpreted in terms of parabolic in the acetonitrile-water system. This behaviour is interpreted in terms of a dual retention mechanism, namely hydrophobic expulsion and polar (presumably silanophilic) interactions. Linear (methanol-water) and parabolic (acetonitrile-water) extrapolations to 0% modifier yielded practically identical log kw values (r2 = 0.980), indicating that for a given stationary phase, log kw is an index of hydrophobic effects independent of specific solute-modifier interactions. The log kw values correlate well with calculated log Poct values (r2 = 0.962 and 0.948).
We also recommend Trading Suppliers and Manufacturers of BUTOXYETHYL NICOTINATE (cas 1322-29-8). Pls Click Website Link as below: cas 1322-29-8 suppliers
Prev:Phase behaviour of a liquid crystalline [1,1'-biphenyl]ol (cas 1322-20-9)yetherester derived from 4′-hydroxy-1,1′-biphenyl-4-carboxylic acid and the ether-d[1,1'-biphenyl]ol (cas 1322-20-9) 4-(3-hydroxypropoxy)butan-1[1,1'-biphenyl]ol (cas 1322-20-9)
Next:Superhydrophobic film based on Cu-dodecanethiol (cas 1322-36-7) complex: Preparation and corrosion inhibition for Cu) - 【Back】【Close 】【Print】【Add to favorite 】