B,N-carbon dots-based ratiometric fluorescent and colorimetric dual-readout sensor for H2O2 and H2O2-involved metabolites detection using ZnFe2O4 magnetic microspheres as peroxidase mimics
-
Add time:08/22/2019 Source:sciencedirect.com
In this work, a two-dimensional optical sensing platform for H2O2, glucose, and uric acid (UA) detection is developed, which integrates the advantages of colorimetric and ratiometric fluorescent techniques. ZnFe2O4 magnetic microspheres with an intrinsic peroxidase-like activity are synthesized to catalyze the oxidation of o-phenylenediamine in the presence of H2O2, producing a typical yellow substance (oxOPD) with an absorption peak at 420 nm. The oxOPD can significantly quench the fluorescence of boron and nitrogen co-doped CDs (B,N-CDs) at 430 nm through the inner filter effect and generate a new fluorescence emission peak at 556 nm. Thus, the fluorescence intensity ratio (I556/I430) can be utilized for quantitative analysis of the concentrations of H2O2 and H2O2-involved metabolites (glucose and UA). The colorimetric “naked-eye” readout based on the color change of solution can also be established to determine H2O2, glucose, and UA levels. The detection limit based on colorimetric sensing for H2O2, glucose, and UA are 0.09, 0.9, and 0.9 μM, respectively, and 0.1, 8, and 1 μM using ratiometric fluorescent sensing. Furthermore, this strategy can detect glucose and UA in human serum with satisfactory results, and provide potential applications in the detection of metabolites related to H2O2 release.
We also recommend Trading Suppliers and Manufacturers of N 556 (cas 110816-78-9). Pls Click Website Link as below: cas 110816-78-9 suppliers
Prev:IschemiaThe effects of tyrphostine Ag 556 on experimental spinal cord ischemia reperfusion injury
Next:Glycolysis inhibitors among compounds containing aldehydes, ketones, and organic acids☆☆☆) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- IschemiaThe effects of tyrphostine Ag 556 on experimental spinal cord ischemia reperfusion injury08/21/2019
- High strain rate compressive behavior of epoxy LY 556: Radial constraint effect08/20/2019
- Investigation of tyrphostin AG 556 for testicular torsion-induced ischemia reperfusion injury in rat08/19/2019
- Original articleUpregulation of miR-556-5p promoted prostate cancer cell proliferation by suppressing PPP2R2A expression08/18/2019
- Sensitive electrochemical detection of gp120 based on the combination of NBD-556 and gp12008/17/2019


