Comparison of the sliding wear behaviour of self-mated HIPed STELLITE (cas 12638-07-2) 3 and STELLITE (cas 12638-07-2) 6 in a simulated PWR water environment
-
Add time:07/12/2019 Source:sciencedirect.com
Cobalt-based alloys such as STELLITE (cas 12638-07-2) 3 and Stellite 6 are widely used to protect stainless steel surfaces in primary circuit nuclear reactor applications where high resistance to wear and corrosion are required. In this study, self-mated sliding wear of Stellite 3 and Stellite 6 consolidated by hot isostatic pressing were compared. Tests were performed with a pin-on-disc apparatus enclosed in a water-submerged autoclave environment and wear was measured from room temperature up to 250 °C (a representative pressurized water reactor environment). Both alloys exhibit a microstructure of micron-sized carbides embedded in a cobalt-rich matrix. Stellite 3 (higher tungsten and carbon content) contains M7C3 and an eta (η) -carbide whereas Stellite 6 contains only M7C3. Furthermore, the former has a significantly higher carbide volume fraction and hardness than the latter. Both alloys show a significant increase in the wear rate as the temperature is increased but Stellite 3 has a higher wear resistance over the entire range; at 250 °C the wear rate of Stellite 6 is more than five times that of Stellite 3. There is only a minimal formation of a transfer layer on the sliding surfaces but electron backscatter diffraction on cross-sections through the wear scar revealed that wear causes partial transformation of the cobalt matrix from fcc to hcp in both alloys over the entire temperature range. It is proposed that the acceleration of wear with increasing temperature in the range studied is associated with a tribocorrosion mechanism and that the higher carbide fraction in Stellite 3 resulted in its reduced wear rate compared to Stellite 6.
We also recommend Trading Suppliers and Manufacturers of STELLITE (cas 12638-07-2). Pls Click Website Link as below: cas 12638-07-2 suppliers
Prev:Quantitation of nikkomycins in biological fluids by ion-pair reversed-phase high-performance liquid chromatography
Next:Spark plasma sintering of STELLITE (cas 12638-07-2)®-6 superalloy) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Microstructure evolution and crack propagation feature in thermal fatigue of laser-deposited STELLITE (cas 12638-07-2) 6 coating for brake discs07/20/2019
- Wear and corrosion performance of laser-clad low-carbon high-molybdenum STELLITE (cas 12638-07-2) alloys07/21/2019
- High temperature wear resistance and thermal fatigue behavior of STELLITE (cas 12638-07-2)-6/WC coatings produced by laser cladding with Co-coated WC powder07/19/2019
- Thermal stability of a STELLITE (cas 12638-07-2)/steel hardfacing interface during long-term aging07/18/2019
- Microstructure and mechanical properties investigation of STELLITE (cas 12638-07-2) 6 and STELLITE (cas 12638-07-2) 6/TiC coating on ASTM A105 steel produced by TIG welding process07/17/2019
- The effect of traverse speed on deposition efficiency of cold sprayed STELLITE (cas 12638-07-2) 2107/16/2019
- Comparison of STELLITE (cas 12638-07-2) coatings on low carbon steel produced by CGS and HVOF spraying07/15/2019
- Tribological and high-temperature mechanical characterization of cold sprayed and PTA-deposited STELLITE (cas 12638-07-2) coatings07/14/2019
- Spark plasma sintering of STELLITE (cas 12638-07-2)®-6 superalloy07/13/2019


