Clinical investigationRest technetium 99m-sestamibi tomoscintigraphy in hibernating myocardium
-
Add time:08/28/2019 Source:sciencedirect.com
The myocardial uptake of rest-injected technetium 99m sestamibi on single-photon-emission computed tomographic images was assessed in 25 patients. All had an area of myocardial dysfunction that could be related to a coronary artery stenosis. None of the patients had clinical evidence of a myocardial infarction. Three months after revascularization, viability was demonstrated by contrast angiography and center-line analysis in 21 (78%) of the 27 formerly hibernating territories. Among these, none had a transmural defect, and 38% had a normal technetium 99m-sestamibi uptake. The four transmural preoperative defects were located in territories without viability. Eight of the 9 territories that were normal at scintigraphy proved to be viable postoperatively. It is concluded that as long as some residual technetium 99m-sestamibi uptake is present, viable myocardium is also present.
We also recommend Trading Suppliers and Manufacturers of TECHNETIUM SESTAMIBI (cas 113720-90-4). Pls Click Website Link as below: cas 113720-90-4 suppliers
Prev:Mini reviewParathyroid imaging with technetium-99m sestamibi
Next:Postreperfusion myocardial technetium-99m–sestamibi defect corresponds to area at risk: Experimental results from an ischemia–reperfusion porcine model) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- International prospective evaluation of scintimammography with technetium-99m sestamibi: interim results08/30/2019
- Postreperfusion myocardial technetium-99m–sestamibi defect corresponds to area at risk: Experimental results from an ischemia–reperfusion porcine model08/29/2019
- Mini reviewParathyroid imaging with technetium-99m sestamibi08/27/2019
- Clinical evaluation of Technetium-99m sestamibi myocardial perfusion SPECT in diabetes with suspected coronary artery diseases08/26/2019
- Original articleThallium-201 is comparable to technetium-99m-sestamibi for estimating cardiac function in patients with abnormal myocardial perfusion imaging08/25/2019
- Midwest Surgical AssociationEarly-phase technetium-99m sestamibi scintigraphy can improve preoperative localization in primary hyperparathyroidism08/24/2019
- Are Tc-99m-Sestamibi Scans in Patients With Secondary Hyperparathyroidism and Renal Failure Needed?08/23/2019
- Original StudyIs Technetium-99m Sestamibi Imaging Able to Predict Pathologic Nonresponse to Neoadjuvant Chemotherapy in Breast Cancer? A Meta-analysis Evaluating Current Use and Shortcomings08/22/2019
- Association for Academic SurgeryTechnetium-99m sestamibi imaging: are the results dependent on the reviewer?08/21/2019


