First electrochemistry of herbicide PETHOXAMID (cas 106700-29-2) and its quantification using electroanalytical approach from mixed commercial product
-
Add time:07/14/2019 Source:sciencedirect.com
This work present a new approach for the detection of relatively new herbicide PETHOXAMID (cas 106700-29-2) (POA), a first electrochemical behavior and determination based on its oxidation on boron-doped diamond electrode in Britton-Robinson buffer solution at pH 4. Square wave voltammetric technique was used for quantification of POA at anodic potential of 1.35 V vs reference Ag/AgCl electrode. The proposed electroanalytical method is operational in the linear working range from 3 to 100 μM of POA with a limit of detection of 1.37 μM. The developed analytical procedure was successfully tested for determination of this herbicide in standard/spiked river water samples and commercial herbicide Successor T SE/spiked river water samples, offering a simple, fast and inexpensive alternative way of pesticide determining to chromatographic methods employed for this purpose.
We also recommend Trading Suppliers and Manufacturers of PETHOXAMID (cas 106700-29-2). Pls Click Website Link as below: cas 106700-29-2 suppliers
Prev:PETHOXAMID (cas 106700-29-2) dissipation and microbial activity and structure in an agricultural soil: Effect of herbicide rate and organic residues
Next:Optically selective and electrochemically active chemosensors for Cu (II) ions based on a skeleton of 2-(benzylideneamino)-4,5,6,7-tetrachloro-3′,6′-dihydroxyspiro-[isoindoline-1, 9′-xanthen]-3-one) - 【Back】【Close 】【Print】【Add to favorite 】