Short communicationFlow-injection extraction spectrophotometric determination of dichromate with the tetramethylenebis(triphenylphosphonium)cation
-
Add time:08/27/2019 Source:sciencedirect.com
Chromium(VI) (0–5 μg) can be determined spectrophotometrically at 365 nm after flow-injection extraction into chloroform of the ion-associate, tetramethylenebis(triphenylphosphonium) dichromate. The carrier stream is distilled water and the reagent stream contains 1 M sulphuric acid and 0.5% (w/v) tetramethylenebis(triphenylphosphonium) bromide. The sampling rate is 24 h−1. The calibration graph is linear up to 20 μg ml−1 and the detection limit is 0.44 μg ml−1 chromium, based on injection volumes of 250 μl. The system has been applied to the determination of chromium in a range of steels.
We also recommend Trading Suppliers and Manufacturers of TETRAMETHYLENEBIS(TRIPHENYLPHOSPHONIUM BROMIDE) (cas 15546-42-6). Pls Click Website Link as below: cas 15546-42-6 suppliers
Prev:Data ArticleDFT analysis on spectral and NLO properties of (2E)-3-[4-(dimethylamino) phenyl]-1-(naphthalen-2-yl) prop-2-en-1-one; a d-π-A chalcone derivative and its docking studies as a potent hepatoprotective agent
Next:Short communicationFlow-injection extraction spectrophotometric determination of bismuth as tetraiodobismuthate(III) with the tetramethylenebis(triphenylphosphonium) cation) - 【Back】【Close 】【Print】【Add to favorite 】