Boron isotopic separation with Pyrocatechol (cas 120-80-9)-modified resin by chromatography technology: Experiment and numerical simulation
-
Add time:09/01/2019 Source:sciencedirect.com
Boron isotopic separation was investigated experimentally and theoretically on boron-specific adsorbent, namely pyrocatechol-modified resin (CL-RESIN). The static adsorption results with initial boron concentration of 8.648 g L−1 at 25 °C were well fitted by the pseudo-second-order kinetic model and Henry isotherm model, from which relevant parameters were used for subsequent isotopic separation simulation by Aspen Chromatograph. The maximum static boron isotopic separation factor with CL-RESIN was 1.13 at 25 °C, thus adsorption-based boron isotopic separation in a chromatographic column packing with CL-RESIN was further studied by experiments and simulations. 11B had greater affinity with CL-RESIN in concentrated boric acid solution with dynamic boron isotopic separation factor of 1.15 and enriched 10B was collected in effluent. Simulation of boron isotopic separation was completed, and simulated results were in good agreement with experimental breakthrough curves under the same conditions. Furthermore, the dynamic behaviors of boron isotopic separation were predicted by simulation under different operating conditions. Response surface methodology (RSM) was employed to determine optimized operating conditions in a chromatographic column. Consequently, the optimized operating conditions were achieved with flow rate of 1.24 mL min−1, 44 cm column length, 0.46 cm column diameter and feed concentration of 8.648 g L−1.
We also recommend Trading Suppliers and Manufacturers of Pyrocatechol (cas 120-80-9). Pls Click Website Link as below: cas 120-80-9 suppliers
Prev:Boron removal using chelating resins with Pyrocatechol (cas 120-80-9) functional groups
Next:Pyrocatechol (cas 120-80-9) as a surface capping molecule on rutile TiO2 (110)) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Highly sensitive and stable laccase based amperometric biosensor developed on nano-composite matrix for detecting Pyrocatechol (cas 120-80-9) in environmental samples09/03/2019
- Pyrocatechol (cas 120-80-9) as a surface capping molecule on rutile TiO2 (110)09/02/2019
- Boron removal using chelating resins with Pyrocatechol (cas 120-80-9) functional groups08/31/2019
- Kinetics of deposition and stability of Pyrocatechol (cas 120-80-9) –FeIII coordinated films08/30/2019
- Full Length ArticleTyrosinase immobilization on functionalized porous silicon surface for optical monitoring of Pyrocatechol (cas 120-80-9)08/29/2019
- Electrodeposition of Pyrocatechol (cas 120-80-9) based films: Influence of potential scan rate, Pyrocatechol (cas 120-80-9) concentration and pH08/28/2019