Effects of linear and branched polyethylene glycol on PEGylation of recombinant hirudin: Reaction kinetics and in vitro and in vivo bioactivities
-
Add time:08/30/2019 Source:sciencedirect.com
To improve the therapy efficacy of recombinant hirudin variant-2 (HV2), its PEGylation was investigated using linear mPEG-succinimidyl carbonate (mPEG-SC) and branched mPEG2-N-hydroxysuccinimide (mPEG2-NHS). The reaction mixtures of PEGylation were analyzed by RP-HPLC and the mono-PEG-HV2 products were purified by anion exchange chromatography (IEC). Effects of linear and branched PEG on the hydrolysis kinetics of the PEG reagent, the PEGylation kinetics of HV2 and the in vitro and in vivo bioactivity of mono-PEG-HV2 were investigated. The RP-HPLC and IEC analyses showed that linear and branched PEG-HV2 with identical molecular weight had different chromatographic behaviors. The reaction kinetics showed that branched mPEG2-NHS displayed higher hydrolysis rate but lower PEGylation rates than linear mPEG-SC. Consequently, HV2 conjugated with mPEG2-NHS required a greater molar ratio of PEG to HV2 than that of mPEG-SC to achieve the identically desired yield of mono-PEG-HV2. The in vitro and in vivo bioactivities of mono-PEG-HV2 showed that branched PEG-HV2 had higher therapeutic efficacy than linear PEG-HV2 with identical molecular weight. The in vivo bioactivity of mono-B-PEG40k-HV2 (mono-PEG-HV2 derived from 40 kDa branched mPEG2-NHS) had a markedly longer duration in rabbits than did unmodified HV2, which showed its potential to be developed as a candidate antithrombotic drug.
We also recommend Trading Suppliers and Manufacturers of hirudin HV2 (cas 114265-28-0). Pls Click Website Link as below: cas 114265-28-0 suppliers
Prev:Regular ArticlePEGylation kinetics of recombinant hirudin and its application for the production of PEGylated HV2 species
Next:In situ PEGylation of recombinant hirudin on an anion exchange chromatography column) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Regular ArticleExpression, Purification and Characterization of Multigram Amounts of a Recombinant Hybrid HV1-HV2 Hirudin Variant Expressed in Saccharomyces cerevisiae09/04/2019
- Two-step ion-exchange chromatographic purification of recombinant hirudin-II and its C-terminal-truncated derivatives expressed in Pichia pastoris09/03/2019
- PEGylation of recombinant hirudin in mixed aqueous–organic solutions09/02/2019
- Development, validation, and clinical pharmacokinetic application of ultra-performance liquid chromatography/tandem mass spectrometry method for simultaneously determining a novel recombinant hirudin derivative (Neorudin) and its active metabolite in human serum09/01/2019
- In situ PEGylation of recombinant hirudin on an anion exchange chromatography column08/31/2019
- Regular ArticlePEGylation kinetics of recombinant hirudin and its application for the production of PEGylated HV2 species08/29/2019
- Chemical modification of recombinant hirudin with palmitic acid in mixed aqueous-organic solutions08/28/2019


