Highly ordered SBA-16 with low nickel amount for enhanced adsorption of methylene blue
-
Add time:08/30/2019 Source:sciencedirect.com
Highly ordered SBA/16 structure with low concentration of nickel (SBA/16-Ni) was developed. SBA/16-Ni showed body-centered cubic structure containing a spatial group lm3m with pore diameter ranging from 4.5 to 6.0 nm. The Ni2+ ions were set to be on SBA/16 walls to prevent pore clogging. The proposed material was engineered to be an environmentally friendly material for removal of pollutants from the aqueous environments. It was tested as a methylene blue (MB) adsorbent and the results compared with maximum adsorption of SBA/16 and other materials described in the literature. Among them, SBA/16-Ni adsorbed the larger amount of dye. The insertion of Ni+2 ions onto the SBA/16 walls increased the specific surface area, which contributed to increase the interaction between SBA/16 and MB. The applicability of the experimental data to the mathematical models indicated that the adsorption for SBA/16-Ni is predominantly driven by chemisorption, which was demonstrated to bean endothermic process. At room temperature, the value of ΔG° for SBA/16-Ni was shown to be more negative than that of SBA/16, suggesting an increase in the spontaneity of the adsorption. The presence of Ni2+ ions on the material provided a structural environment more favorable for dye molecules being deposited. This idea was strengthened by the more negative ΔS° value of SBA/16-Ni. The Ni2+ ions corrected somewhat structural imperfections on the material surface, creating regular and homogeneously distributed adsorption sites. SBA/16-Ni was shown to be a useful adsorbent with excellent performance for removal of pollutants.
We also recommend Trading Suppliers and Manufacturers of Blue 16 (cas 1342-79-6). Pls Click Website Link as below: cas 1342-79-6 suppliers
Prev:Article (Special Issue of the International Symposium on Single-Atom Catalysis (ISSAC-2016))Identification of active sites for hydrogenation over Ru/SBA-15 using in situ Fourier-transform infrared spectroscopy
Next:What is so unappealing about blue food and drink?) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Original contributionDiagnosis of urothelial carcinoma in situ using blue light cystoscopy and the utility of immunohistochemistry in blue light–positive lesions diagnosed as atypical☆☆☆★09/02/2019
- Euphemisms and non-proximal manipulation of discourse space: The case of blue-on-blue09/01/2019
- What is so unappealing about blue food and drink?08/31/2019


