Optimizing the insulation thickness of external wall by a novel 3E (energy, environmental, economic) method
-
Add time:07/15/2019 Source:sciencedirect.com
One of the main challenges in the building industry is determining the thickness and material of insulations that are used in the external wall. The selection of the above-mentioned parameters depends upon various aspects, including energy, environment, and economy. In many cases, the analysis which is carried out based on each of these aspects leads to different results. In the present study, a comprehensive analysis was carried out based on energy, environment, and economy criteria where the energy, environment, and economic costs of producing insulations are also taken into account. Accordingly, material and optimum thickness of insulation for the external wall of an office building were determined. The results showed that Polyurethane with the thickness of 8 cm, EPS with the thickness of 20 cm, and Rockwool with the thickness of 7 cm were optimum states with regard to the aspects of energy, environment, and economy respectively. Finally, a novel function, which considered all three parameters simultaneously, was defined. Consequently, 3E (energy, environmental, and economic) analysis was carried out and led to the presentation of the Mineral wool insulation with the thickness of 11 cm as the optimum state of investigated cases according to the 3E criterion.
We also recommend Trading Suppliers and Manufacturers of (3E)-1,2,3,4,5,6-hexachlorohex-3-ene (cas 1725-74-2). Pls Click Website Link as below: cas 1725-74-2 suppliers
Prev:Cyclic oligomers in the cationic polymerization of cis- and trans-2,3-dimethylthiirane
Next:Energy, exergy and environmental (3E) analysis of the existing CHP system in a petrochemical plant) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- A 3E evaluation on the interaction between environmental impacts and costs in a hydrogen liquefier combined with absorption refrigeration systems07/22/2019
- Employing photovoltaic/thermal panels as a solar chimney roof: 3E analyses and multi-objective optimization07/20/2019
- Semaphorin 3E regulates apoptosis in the intestinal epithelium during the development of colitis07/21/2019
- Energy, economic and environmental (3E) analysis and multi-objective optimization of a spray-assisted low-temperature desalination system07/19/2019
- Impacts of the 3E (economy, energy and environment) coordinated development on energy mix in China: The multi-objective optimisation perspective07/18/2019
- The adjusted optical properties for Galileo/BeiDou-2/QZS-1 satellites and initial results on BeiDou-3e and QZS-2 satellites07/17/2019
- Energy, exergy and environmental (3E) analysis of the existing CHP system in a petrochemical plant07/16/2019