Lipoprotein(a) determination in human serum using a Nitrilotriacetic acid (cas 139-13-9) derivative immunosensing scaffold on disposable electrodes
-
Add time:09/29/2019 Source:infona.pl
A novel strategy for the construction of a disposable integrated amperometric immunosensor for the sensitive and rapid determination of lipoprotein(a) (Lp(a)), an important predictor of cardiovascular disease risk, in human serum is reported. The approach uses a sandwich format involving the covalent immobilization of selective capture antibodies (antiLp(a)) on the surface of N-[N α,N α-bis(carboxymethyl)-lysine]-12-mercaptododecanamide (HS-NTA)-modified screen-printed carbon electrodes (SPCEs). After a blocking step with skimmed milk, the modified antiLp(a)-SPCEs were incubated with a mixture solution containing the target analyte and a fixed concentration of a specific biotinylated antibody (biotin-antiLp(a)) and a streptavidin-horseradish peroxidase (HRP) (Strep-HRP) conjugate. The amperometric responses of the resulting immunosensor at −0.10 V (vs an Ag pseudo-reference electrode), upon addition of 3,3′,5,5′-tetramethylbenzidine (TMB) as electron transfer mediator and H2O2 as the enzyme substrate, were used to monitor the extent of the immunoreactions. The developed methodology exhibited a wide range of linearity between 0.02 and 10 μg mL−1, a low detection limit (LOD) of 8 ng mL−1, and a great selectivity against other serum components. The usefulness of the Lp(a) immunosensor was demonstrated by analyzing spiked serum samples as well as a reference serum containing a certified Lp(a) content.
We also recommend Trading Suppliers and Manufacturers of Nitrilotriacetic acid (cas 139-13-9). Pls Click Website Link as below: cas 139-13-9 suppliers
Prev:Different Patterns of Kidney Toxicity after Subacute Administration of Na-Nitrilotriacetic acid (cas 139-13-9) and Fe-Nitrilotriacetic acid (cas 139-13-9) to Wistar Rats
Next:High-accuracy determination of iron in seawater by isotope dilution multiple collector inductively coupled plasma mass spectrometry (ID-MC-ICP-MS) using Nitrilotriacetic acid (cas 139-13-9) chelating resin for pre-concentration and matrix separation) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- High-accuracy determination of iron in seawater by isotope dilution multiple collector inductively coupled plasma mass spectrometry (ID-MC-ICP-MS) using Nitrilotriacetic acid (cas 139-13-9) chelating resin for pre-concentration and matrix separation09/30/2019
- Different Patterns of Kidney Toxicity after Subacute Administration of Na-Nitrilotriacetic acid (cas 139-13-9) and Fe-Nitrilotriacetic acid (cas 139-13-9) to Wistar Rats10/01/2019
-
Health and Chemical more >