Miniaturization overcomes macro sample analysis limitations: Salicylate-selective polystyrene nanoparticle-modified optical sensor
-
Add time:07/16/2019 Source:sciencedirect.com
Salicylate-selective polystyrene micro-optode is engineered using a mixed solvent method. The size of the particles (200–400 nm) and the distribution of the recognition components onto their surface were elucidated by transmission electron microscope and confocal fluorescence microscope. The polystyrene micro/nanoparticles are modified with thiourea derivative as ionophore, ETH 7075 as chromoionophore, and tridodecylmethyl ammonium chloride (TDMAC) as ion-exchanger. The response mechanism depends on the selective binding of the ionophore at the surface of the particles to salicylate. A concomitant protonation of the chromoionophore results in a decrease in the absorbance at the maximum wavelength, 535 nm. Enabling this sensing interaction at the micro-scale decreases the response time of the optode to be lower than 10 s the concentration range of 3–70 µM, with a detection limit of 2.1 μM. This microsphere sensing platform demonstrated excellent performance in the determination of salicylate in spiked urine samples and in pharmaceutical formulations. Further miniaturization of these micro-optodes promises in-vivo analysis of intracellular analytes.
We also recommend Trading Suppliers and Manufacturers of octadecyl salicylate (cas 14971-14-3). Pls Click Website Link as below: cas 14971-14-3 suppliers
Prev:Lipase-catalyzed chemospecific O-acylation of 3-mercapto-1-propanol and 4-MERCAPTO-1-BUTANOL (cas 14970-83-3)
Next:Calixarene-doped PVC polymeric films as size-selective optical sensors: Monitoring of salicylate in real samples) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Bulk purification of isochorismic acid by low-pressure octadecyl (C18) reverse-phase liquid chromatography07/23/2019
- Determination of salicylate hydroxylation products as an in vivo oxidative stress marker07/22/2019
- Combined liquid and solid-surface room temperature fluorimetric determination of naproxen and salicylate in serum07/20/2019
- Optimization of matrix solid-phase dispersion for the rapid determination of salicylate and benzophenone-type UV absorbing substances in marketed fish07/21/2019
- Separation behavior of inorganic anions on an octadecyl-bonded silica column coated with cetyltrimethylammonium by phthalate and salicylate eluents07/19/2019
- Highly selective thiourea-based bulk optode for determination of salicylate in spiked urine samples, Aspirin® and Aspocid®07/18/2019
- Calixarene-doped PVC polymeric films as size-selective optical sensors: Monitoring of salicylate in real samples07/17/2019
-
Health and Chemical more >


