Quantification of ondansetron, granisetron and tropisetron in goat plasma using hydrophilic interaction liquid chromatography-solid phase extraction coupled with hydrophilic interaction liquid chromatography-triple quadrupole tandem mass spectrometry
-
Add time:07/20/2019 Source:sciencedirect.com
An assay method to quantify ondansetron (OND), granisetron (GRA) and tropisetron (TRO) in goat plasma has been successfully developed and validated. This method procedure for the analysis of OND, GRA and TRO was involved of extracting samples with hydrophilic interaction liquid chromatography (HILIC) solid phase extraction (SPE) and determination by liquid chromatography coupled to tandem mass spectroscopy. An SPE method for the simultaneous extraction of OND, GRA and TRO with high efficiency and selectivity was developed. Prior to HPLC-MS/MS analysis, most of the sources of interference present in the supernatant after protein precipitation of plasma proteins was efficiently removed from the samples by the HILIC SPE treatment. For the quantification of OND, GRA and TRO in the samples, tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used. The calibration curve was performed in the range of 0.2–20 ng/mL for the target OND, GRA and TRO in goat plasma samples. The precision of the intra- and inter-day assay for OND, GRA and TRO were 1.84–6.23% and 3.89–5.31%, 2.63–6.29% and 3.76–5.31%, 1.99–5.67% and 2.64–4.70%, respectively. The accuracy of the intra- and inter-day assay for OND, GRA and TRO were 89.15–97.39% and 89.46–95.17%, 91.08–100.82% and 91.24–99.47%, 92.30–100.74% and 94.21–97.90%, respectively. For the determination of OND, GRA and TRO in plasma samples, no significant matrix effects were observed. The mean absolute recoveries were 103–150%, 115–121%, and 98–141% for OND, GRA and TRO, respectively. Furthermore, the mean process efficiency values of silica SPE were 98–135%, 92–124%, and 72–109% for OND, GRA and TRO, respectively.
We also recommend Trading Suppliers and Manufacturers of Tropisetron hydrochloride (cas 105826-92-4). Pls Click Website Link as below: cas 105826-92-4 suppliers
Prev:The effects of the 5-HT3 receptor antagonist tropisetron on cocaine-induced conditioned taste aversions
Next:Determination of tropisetron in human plasma by high performance liquid chromatographic method with UV detection and its application to a bioequivalence study) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Experimental examination of anti-inflammatory effects of a 5-HT3 receptor antagonist, tropisetron, and concomitant effects on autonomic nervous function in a rat sepsis model07/24/2019
- Ameliorating effects of tropisetron on dopaminergic disruption of prepulse inhibition via the α7 nicotinic acetylcholine receptor in Wistar rats07/23/2019
- Determination of tropisetron in human plasma by high performance liquid chromatographic method with UV detection and its application to a bioequivalence study07/22/2019
- The effects of the 5-HT3 receptor antagonist tropisetron on cocaine-induced conditioned taste aversions07/21/2019
- Tropisetron as a neuroprotective agent against glutamate-induced excitotoxicity and mechanisms of action07/19/2019
- Tropisetron inhibits sepsis by repressing hyper-inflammation and regulating the cardiac action potential in rat models07/18/2019
-