Synthesis, characterization and ethanol sensing properties of peripheral and non-peripheral tetrakis-(3,6-dihexyl-7-oxy-4-methylcoumarin)substituted zinc(II), cobalt(II), and copper(II) phthalocyanines
-
Add time:08/20/2019 Source:sciencedirect.com
Phthalocyanines bearing coumarin moiety may exhibit interesting properties and also can soluble in organic solvents, easily. In this work, the phthalocyanine compounds bearing tetra-(3,6-dihexyl-7-oxy-4-methylcoumarin) units were synthesized and characterized. Firstly, the starting coumarin compound was synthesized by Pechmann condensation and then phthalonitrile compounds were synthesized by nucleofilic aromatic substitution. Phthalocyanine compounds were synthesized by cyclotetramerization of phthalonitriles. These compounds were characterized by spectroscopic methods such as FT-IR, 1H NMR, 13C NMR, electronic absorption spectra, MALDI-TOF mass and elemental analyses as well. The effect of the structure (position of substitution, central metal atom, etc.) of phthalocyanines on electronic absorption spectra and aggregation behavior was also investigated in this paper. In another set of experiments, the effects of the position of methylcoumarin substituent on ethanol vapor sensing performance of the synthesized compounds were investigated and discussed. The observed sensitivities of peripheral and non-peripheral substituted phthalcyanine films are different in spite of their similar bond numbers, indicating significant role of position of the substituent in interaction mechanism. According to the results, the peripheral substituted Pc based sensor not only had high sensitivity towards ethanol vapor, but exhibited very short response time and recovery times. When the concentration of ethanol reached 250 ppm, sensitivity and the response time of peripheral substituted CoPc reached 1.1 × 10−2 ppm−1 which was two-fold that than of non-peripheral substitueted CoPc. While peripheral substituted CoPc based sensor shows a response time of 70 s towards 250 ppm concentration of ethanol vapor, the response time of the non-peripheral substitueted CoPc based sensor was about 270 s. As a result, the presented peripheral methyl coumarin substituted compounds are good candidates for ethanol sensing applications.
We also recommend Trading Suppliers and Manufacturers of DIHEXYL ETHER (cas 112-58-3). Pls Click Website Link as below: cas 112-58-3 suppliers
Prev:NoteThe thermodynamics of 1,4,7,10,13- pentaazatridecane complexes of silver(I) in dimethyl sulfoxide
Next:Critical properties of some aliphatic symmetrical ethers) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Decomposition of dioxiranes induced by dialkyl ethers08/28/2019
- Mechanism, ab initio calculations and microkinetics of straight-chain alcohol, ether, ester, aldehyde and carboxylic acid hydrodeoxygenation over Ni-Mo catalyst08/27/2019
- Asymmetric deprotonation of N,N-dihexyl-1-naphthamides to provide atropisomers of N,N-dihexyl-2-alkyl-1-naphthamides08/26/2019
- Conjugated copolymers based on dihexyl-benzimidazole moiety for organic photovoltaics08/25/2019
- Synthesis and characterization of low-bandgap copolymers based on dihexyl-2H-benzimidazole and terthiophene08/24/2019
- Copolymer derived from dihexyl-2H-benzimidazole and carbazole for organic photovoltaic cells08/23/2019
- Hematoporphyrin ethers—II. Improvements in method, synthesis of the dihexyl, dicyclohexanyl and diphenyl ethers and their preliminary biological evaluation08/22/2019
- Critical properties of some aliphatic symmetrical ethers08/21/2019
-
Health and Chemical more >


