Welcome to LookChem.com Sign In | Join Free

Science Details

Home > Chemical Encyclopedia > Science List > Details
  • Chemically modified carbon paste and membrane sensors for the determination of Benzethonium chloride (cas 121-54-0) and some anionic surfactants (SLES, SDS, and LABSA): Characterization using SEM and AFM

  • Add time:09/08/2019    Source:sciencedirect.com

    Chemically modified carbon-paste (CMCP) and membrane- sensors based on incorporating benzothonium-tetraphenylborate (BT-TPB) were constructed for the analysis of Benzethonium chloride (cas 121-54-0), and some other surfactants such as sodium lauryl ether sulphate (SLES), sodium dodecyl sulphate (SDS), and linear alkylbenzene sulphonic acid (LABSA). All sensors showed good sensitivity and reverse wide linearity over a concentration range of 5.97×10−7 to 1.00×10−3 and 5.96×10−7 to 3.03×10−3 mol L−1 with limit of detection of 3.92×10−7and 3.40×10−7 mol L−1 for membrane and chemically modified carbon paste sensors, respectively, with respect to benzethonium chloride (BT.Cl). They could be used over a wide pH range of 2.0–10.0. The thermal coefficients of membrane and CMCP sensors are 5.40×10−4, 1.17×10−4 V/°C, respectively. The sensors indicated a wide selectivity over different inorganic cations. The effect of soaking on the surface morphology of the membrane sensor was studied using EDX-SEM and AFM techniques. The response time was <10 s The freshly prepared, exhausted membrane, and CMCP sensors were successfully applied for the potentiometric determination of the pure BT.Cl solution. They were also used for the determination of its pharmaceutical formulation Dermoplast® antibacterial spray (20% benzocaine+0.2% benzethonium chloride) with recovery values ranging from 97.54±1.70 to 101.25±1.12 and from 96.32±2.49 to 101.23±2.15%. The second goal of these sensors is the potentiometric determination of different surfactants such as SLES, SDS, and LABSA with good recovery values using BT.Cl as a titrant in their pure forms, and in samples containing one of them (shampoo, Touri® dishwashing liquid, and waste water). The statistical analysis of the obtained data was studied.

    We also recommend Trading Suppliers and Manufacturers of Benzethonium chloride (cas 121-54-0). Pls Click Website Link as below: cas 121-54-0 suppliers

    Prev:Theoretical and cyclic voltammetric studies on electrocatalysis of Benzethonium chloride (cas 121-54-0) at carbon paste electrode for detection of dopamine in presence of ascorbic acid
    Next:On the effect of Benzethonium intercalation process: Structural and dielectric properties of exchanged montmorillonite)

  • Back】【Close 】【Print】【Add to favorite
Periodic Table
    Related Products