Synergistic integration of sonochemical and electrochemical disinfection with DSA (cas 138685-19-5) anodes
-
Add time:09/25/2019 Source:sciencedirect.com
This work focuses on the disinfection actual urban wastewater by the combination of ultrasound (US) irradiation and electrodisinfection with Dimensionally Stable Anodes (DSA (cas 138685-19-5)). First, the inactivation of Escherichia coli (E. coli) during the sonochemical disinfection was studied at increasing ultrasound power. Results showed that it was not possible to achieve a complete disinfection, even at the highest US power (200 W) dosed by the experimental device used. Next, the electrodisinfection with DSA anodes at different current densities was studied, finding that it was necessary a minimum current density of 11.46 A m−2 to reach the complete disinfection. Finally, an integrated sonoelectrodisinfection process was studied. Results showed a synergistic effect when coupling US irradiation with DSA electrodisinfection, with a synergy coefficient higher than 200% of the disinfection rate attained for the highest US power applied. In this process, hypochlorite and chloramines were identified as the main reagents for the disinfection process (neither chlorate nor perchlorate were detected), and the presence of trihalomethanes was far below acceptable values. Confirming this synergistic effect with DSA anodes opens the door to novel efficient disinfection processes, limiting the occurrence of hazardous disinfection by-products.
We also recommend Trading Suppliers and Manufacturers of DSA (cas 138685-19-5). Pls Click Website Link as below: cas 138685-19-5 suppliers
Prev:Electrochemical degradation of 17-α-Methyltestosterone over DSA (cas 138685-19-5)® electrodes
Next:CLINICAL STUDYEffectiveness of MRA on embolized intracranial aneurysms: a comparison of DSA (cas 138685-19-5), CE-MRA, and TOF-MRA) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Impact of persistent and cleared preformed HLA DSA (cas 138685-19-5) on kidney transplant outcomes09/27/2019
- CLINICAL STUDYEffectiveness of MRA on embolized intracranial aneurysms: a comparison of DSA (cas 138685-19-5), CE-MRA, and TOF-MRA09/26/2019
- Electrochemical degradation of 17-α-Methyltestosterone over DSA (cas 138685-19-5)® electrodes09/24/2019
- Comparative study of 4D CTA and DSA (cas 138685-19-5) for vascular assessment in moyamoya disease09/10/2019
- Physicochemical softening of a bituminous binder by a reactive surfactant (dodecenyl succinic anhydride, DSA (cas 138685-19-5))09/09/2019
- Technical noteReviews the research on some dimensionally stable anodes (DSA (cas 138685-19-5)) based on titanium09/08/2019
- Technical NoteA comparison between DART-MS and DSA (cas 138685-19-5)-MS in the forensic analysis of writing inks09/07/2019
- Assessing the performance of electrochemical oxidation using DSA (cas 138685-19-5) and BDD anodes in the presence of UVC light09/06/2019
- Importance of HLA typing, PRA and DSA (cas 138685-19-5) tests for successful parathyroid allotransplantation09/05/2019


