Capacitance comparison of poly(Indole-5-carboxylic acid (cas 1670-81-1)) in different electrolytes and its symmetrical supercapacitor in HClO4 aqueous electrolyte
-
Add time:09/26/2019 Source:sciencedirect.com
In this work, poly(indole-5-carboxylic acid) (PICA) nanowires were facilely prepared by a one-step electrodeposition on glass carbon electrode (GC) and its capacitance performance was evaluated in different electrolytes. The initial galvanostatic charge/discharge test of PICA in acetonitrile/LiClO4 exhibited a specific capacitance of 275 F g−1 at the current density of 1.0 A g−1 but the capacitance stability was quite poor, whereas, an enhanced specific capacitance (350 F g−1 at 1.0 A g−1) and an improved capacitance stability (98% capacitance retention after 1000 cycles) were obtained in HClO4 aqueous electrolyte, which were also better than that in the counterpart media (Na2SO4, KCl, and H2SO4 aqueous electrolytes). Additionally, the symmetrical supercapacitor based on two PICA electrodes in HClO4 aqueous electrolyte exhibited a maximum specific capacitance of 69.0 F g−1, an energy density of 9.4 Wh kg−1 at a power density of 1000 W kg−1, and an excellent cycle life of 94% specific capacitance retention after 1000 cycles. These results implied that the PICA nanowires with HClO4 aqueous solution as electrolyte will be a kind of promising electrode material for supercapacitors.
We also recommend Trading Suppliers and Manufacturers of Indole-5-carboxylic acid (cas 1670-81-1). Pls Click Website Link as below: cas 1670-81-1 suppliers
Prev:Research paperCation-π-complex of Ag(I) ion with 1H-Indole-5-carboxylic acid (cas 1670-81-1) – Structural analysis and energetics of the M–L bonds
Next:Selective detection of dopamine on poly(Indole-5-carboxylic acid (cas 1670-81-1))/tyrosinase electrode) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Immobilization of rat brain acetylcholinesterase on ZnS and poly(Indole-5-carboxylic acid (cas 1670-81-1)) modified Au electrode for detection of organophosphorus insecticides09/30/2019
- Construction of an amperometric glycated hemoglobin biosensor based on Au–Pt bimetallic nanoparticles and poly (Indole-5-carboxylic acid (cas 1670-81-1)) modified Au electrode09/29/2019
- A new synthesis of indole 5-carboxylic acids and 6-hydroxy-Indole-5-carboxylic acid (cas 1670-81-1)s in the preparation of an o-hydroxylated metabolite of vilazodone09/28/2019
- Inhibitive action of Indole-5-carboxylic acid (cas 1670-81-1) towards corrosion of mild steel in deaerated 0.5 M sulfuric acid solutions10/01/2019
- Selective detection of dopamine on poly(Indole-5-carboxylic acid (cas 1670-81-1))/tyrosinase electrode09/27/2019
- Research paperCation-π-complex of Ag(I) ion with 1H-Indole-5-carboxylic acid (cas 1670-81-1) – Structural analysis and energetics of the M–L bonds09/25/2019
- Photophysics of indole-2-carboxylic acid (I2C) and Indole-5-carboxylic acid (cas 1670-81-1) (I5C): Heavy atom effect09/24/2019
- Facile construction of poly (indole‑5‑carboxylic acid) @ poly (3, 4‑ethylenedioxythiophene) label-free immunosensing platform for sensitive detection of prostate specific antigen09/10/2019
-
Health and Chemical more >


