Selective detection of dopamine on poly(Indole-5-carboxylic acid (cas 1670-81-1))/tyrosinase electrode
-
Add time:09/27/2019 Source:sciencedirect.com
We report here on a simple tyrosinase (TYR) modified electrode designed through the covalent bonding of the enzyme with poly (indole-5-carboxylic acid) (PIn5COOH) conducting polymer. This electrode was applied to the amperometric detection of dopamine (DA) in the presence of ascorbic acid (AA), uric acid (UA) and their mixtures, in the concentration range and ratios similar to those found in blood serum. Our experiments demonstrate that the presence of these interferents (AA, UA) does not affect the selectivity of such electrode towards dopamine with linear concentration dependence in the range of 0.5–20 μM, depending on the experimental conditions, however its sensitivity depends on the type and amount of interferent present. The lower limit of detection of DA in the presence of high AA (1000 fold) or UA (500 fold) concentration was found to be 0.1–0.5 μM. The sensitivity for DA detection is 6.2 A/M cm2 with UA and 2.3 A/M cm2 with AA present as interfering agents. For both interferents present in the ratio 12.5:1 (AA:UA), the sensitivity drops to the value of ca. 1.3 A/M cm2. The Michaelis–Menten (KM) constant and Imax values were evaluated, showing improved electrode sensitivity towards dopamine as judged from the decrease of the Michaelis–Menten constant.
We also recommend Trading Suppliers and Manufacturers of Indole-5-carboxylic acid (cas 1670-81-1). Pls Click Website Link as below: cas 1670-81-1 suppliers
Prev:Capacitance comparison of poly(Indole-5-carboxylic acid (cas 1670-81-1)) in different electrolytes and its symmetrical supercapacitor in HClO4 aqueous electrolyte
Next:Inhibitive action of Indole-5-carboxylic acid (cas 1670-81-1) towards corrosion of mild steel in deaerated 0.5 M sulfuric acid solutions) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Immobilization of rat brain acetylcholinesterase on ZnS and poly(Indole-5-carboxylic acid (cas 1670-81-1)) modified Au electrode for detection of organophosphorus insecticides09/30/2019
- Construction of an amperometric glycated hemoglobin biosensor based on Au–Pt bimetallic nanoparticles and poly (Indole-5-carboxylic acid (cas 1670-81-1)) modified Au electrode09/29/2019
- A new synthesis of indole 5-carboxylic acids and 6-hydroxy-Indole-5-carboxylic acid (cas 1670-81-1)s in the preparation of an o-hydroxylated metabolite of vilazodone09/28/2019
- Inhibitive action of Indole-5-carboxylic acid (cas 1670-81-1) towards corrosion of mild steel in deaerated 0.5 M sulfuric acid solutions10/01/2019
- Capacitance comparison of poly(Indole-5-carboxylic acid (cas 1670-81-1)) in different electrolytes and its symmetrical supercapacitor in HClO4 aqueous electrolyte09/26/2019
- Research paperCation-π-complex of Ag(I) ion with 1H-Indole-5-carboxylic acid (cas 1670-81-1) – Structural analysis and energetics of the M–L bonds09/25/2019
- Photophysics of indole-2-carboxylic acid (I2C) and Indole-5-carboxylic acid (cas 1670-81-1) (I5C): Heavy atom effect09/24/2019
- Facile construction of poly (indole‑5‑carboxylic acid) @ poly (3, 4‑ethylenedioxythiophene) label-free immunosensing platform for sensitive detection of prostate specific antigen09/10/2019
-
Health and Chemical more >


