Regular articleReliable Gene Expression Profiling from Small and HEMATOXYLIN (cas 1412-19-7) and Eosin–Stained Clinical Formalin-Fixed, Paraffin-Embedded Specimens Using the HTG EdgeSeq Platform
-
Add time:09/29/2019 Source:sciencedirect.com
Clinical biomarker studies are often hindered by the scarcity or suboptimal quality of biological specimens. EdgeSeq, a transcriptomics analysis platform, combines quantitative nuclease protection assay technology with next-generation sequencing, using small amounts of starting material and delivering reproducible gene expression profiles from challenging material, such as formalin-fixed, paraffin-embedded (FFPE) tissue. To evaluate EdgeSeq for analysis of archives of stained FFPE tissue, EdgeSeq was performed on unstained, HEMATOXYLIN (cas 1412-19-7) and eosin (H&E)–stained, and immunohistochemistry-stained slides from patients with small-cell and non–small-cell lung cancer. Pairwise comparisons of gene expression profiles from stained and unstained slides showed higher Pearson correlation coefficients with H&E staining (0.86 to 0.97) than with immunohistochemistry staining (0.21 to 0.56). A 25-gene interferon-γ signature score from unstained slides showed a Pearson correlation coefficient of 0.92 with H&E-stained slides and a significant Spearman correlation (P = 0.0025) with immune scores. To test gene expression profiling in small samples, FFPE sample equivalents were examined from 5.0 to 0.08 mm2 of a section (5 μm thick); sample equivalents ≥0.31 mm2 showed alignment rates >69% and pairwise Pearson correlation coefficients ≥0.87. EdgeSeq can, thus, be used to profile small and H&E-stained FFPE tumor specimens to obtain biomarker data from limited tissue in oncology clinical trials and enable research into tumor microenvironment and immune cell engagement with tumors at the locoregional level.
We also recommend Trading Suppliers and Manufacturers of HEMATOXYLIN (cas 1412-19-7). Pls Click Website Link as below: cas 1412-19-7 suppliers
Prev:Adsorption and deposition-assisted anodic stripping voltammetry for determination of antimony(III) in presence of HEMATOXYLIN (cas 1412-19-7) on glassy carbon electrode
Next:A study of the electrochemical behavior of HEMATOXYLIN (cas 1412-19-7) as an important bioactive flavonoid) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- A study of the electrochemical behavior of HEMATOXYLIN (cas 1412-19-7) as an important bioactive flavonoid09/30/2019
- Adsorption and deposition-assisted anodic stripping voltammetry for determination of antimony(III) in presence of HEMATOXYLIN (cas 1412-19-7) on glassy carbon electrode09/28/2019
- Synthesis and properties of synthetic fulvic acid derived from HEMATOXYLIN (cas 1412-19-7)10/01/2019
- Full paperRotational wind power triboelectric nanogenerator using aerodynamic changes of friction area and the adsorption effect of HEMATOXYLIN (cas 1412-19-7) onto feather based on a diversely evolved hyper-branched structure09/27/2019
- Unsupervised method for normalization of HEMATOXYLIN (cas 1412-19-7)-eosin stain in histological images09/26/2019
- Technical noteHEMATOXYLIN (cas 1412-19-7) assay of cupric chelation can give false positive results09/25/2019
- Review articleThe HEMATOXYLIN (cas 1412-19-7) and eosin stain in anatomic pathology—An often-neglected focus of quality assurance in the laboratory09/24/2019


