Angewandte
Chemie
[1] A. Manz, J. C. T. Eijkel, Pure Appl. Chem. 2001, 73, 1555 – 1561.
[2] a) J. Atencia, D. J. Beebe, Nature 2005, 437, 648 – 655; b) V.
Hessel, H. Löwe, Chem. Eng. Technol. 2005, 28, 267 – 284; c) J.
Kobayashi, Y. Mori, K. Okamoto, R. Akiyama, M. Ueno, T.
Kitamori, S. Kobayashi, Science 2004, 304, 1305 – 1308; d) S. J.
Haswell, R. J. Middleton, B. OꢀSullivan, V. Skelton, P. Watts, P.
Styring, Chem. Commun. 2001, 5, 391 – 398; e) D. Erickson, D.
Li, Anal. Chim. Acta 2004, 507, 11 – 26; f) M. Tokeshi, Y.
Kikutani, A. Hibara, K. Sato, H. Hisamoto, T. Kitamori,
Electrophoresis 2003, 24, 3583 – 3594; g) T. Vilkner, D. Janasek,
A. Manz, Anal. Chem. 2004, 76, 3373 – 3385; h) M. Brivio, R. H.
Fokkens, W. Verboom, D. N. Reinhoudt, N. R. Tas, M. Goedb-
loed, A. van den Berg, Anal. Chem. 2002, 74, 3972 – 3976; i) P. S.
Dittrich, P. Schwille, Anal. Chem. 2003, 75, 5767 – 5774; j) K.
Jähnisch, V. Hessel, H. Löwe, M. Baerns, Angew. Chem. 2004,
116, 410 – 453; Angew. Chem. Int. Ed. 2004, 43, 406 – 446; k) F.
Schönfeld, V. Hessel, C. Hofmann, Lab Chip 2004, 4, 65 – 69;
l) A. E. Guber, M. Heckele, D. Herrmann, A. Muslija, V. Saile,
L. Eichhorn, T. Gietzelt, A. Hoffmann, P. C. Hauser, J.
Tanyanyiwa, A. Gerlach, N. Gottschlich, G. Knebel, Chem.
Eng. J. 2004, 101, 447 – 453; m) M. Kakuta, F. G. Bessoth, A.
Manz, Chem. Rec. 2001, 1, 395 – 405; n) C. Erbacher, F. G.
Bessoth, M. Busch, E. Verpoorte, A. Manz, Mikrochim. Acta
1999, 131, 19 – 24; o) M. Grumann, A. Geipel, L. Riegger, R.
Zengerle, J. Ducrꢁe, Lab Chip 2005, 5, 560 – 565.
Figure 4. Monitoring reaction kinetics with stacked electropherograms.
For this purpose the wild-type enzyme and substrate were pipetted
together in a microvial on a chip and repetitive chiral separations were
preformed.
[3] a) D. Belder, M. Ludwig, Electrophoresis 2003, 24, 2422 – 2430;
b) M. Ludwig, F. Kohler, D. Belder, Electrophoresis 2003, 24,
3233 – 3238; c) D. Belder, M. Ludwig, Electrophoresis 2003, 24,
3595 – 3606; d) D. Belder, A. Deege, M. Maass, M. Ludwig,
Electrophoresis 2002, 23, 2355 – 2361.
[4] a) L. D. Hutt, D. P. Glavin, J. L. Bada, R. A. Mathies, Anal.
Chem. 1999, 71, 4000 – 4006; b) S. R. Wallenborg, I. S. Lurie,
D. W. Arnold, C. G. Bailey, Electrophoresis 2000, 21, 3257 –
3263; c) I. Rodriguez, L. J. Jin, S. F. Y. Li, Electrophoresis 2000,
21, 211 – 219; d) H. Wang, Z. P. Dai, L. Wang, J. L. Bai, B. C. Lin,
Chin. J. Anal. Chem. 2002, 30, 665 – 669; e) M. A. Schwarz, P. C.
Hauser, J. Chromatogr. A 2001, 928, 225 – 232; f) E. ꢂlvecka, M.
Masar, D. Kaniansky, M. Jöhnck, B. Stanislawski, Electropho-
resis 2001, 22, 3347 – 3353; g) S. Il Cho, K. N. Lee, Y. K. Kim,
J. H. Jang, D. S. Chung, Electrophoresis 2002, 23, 972 – 977;
h) B. F. Liu, M. Ozaki, Y. Utsumi, T. Hattori, S. Terabe, Anal.
Chem. 2003, 75, 36 – 41.
[5] N. Piehl, M. Ludwig, D. Belder, Electrophoresis 2004, 25, 3848 –
3852.
[6] M. T. Reetz, K. M. Kꢃhling, A. Deege, H. Hinrichs, D. Belder,
Angew. Chem. 2000, 112, 4049 – 4052; Angew. Chem. Int. Ed.
2000, 39, 3891 – 3893.
Figure 5. Slope for conversion and E value, derived from data of
stacked electropherograms in Figure 4.
solution of epoxide hydrolase of the wild-type enzyme and
with 10 mL of 0.75 mmolLÀ1 of epoxide solution.
Herein we have demonstrated the first example of an
integrated chip-based system applied in synthetic chemistry
and catalysis which integrates a microfluidic reactor with
chemical analysis. In this initial study the device was success-
fully applied for testing enantioselective biocatalysts created
by directed evolution of enzymes; the device also has great
potential for high-throughput screening. Integration of chem-
ical reaction and analysis on a chip results in reduced reagent
consumption and allows the speed of the whole screening
process to be increased considerably. Further improvement of
the system, with regard to high-throughput appears possible
by implementing faster and more effective micromixers, by
parallelization of the microfluidic separation and reaction
channels and/or by coupling with microdroplet devices as
previously suggested.[17]
[7] R. Pal, M. Yang, R. Lin, B. N. Johnson, N. Srivastava, S. Z.
Razzacki, K. J. Chomistek, D. C. Heldsinger, R. M. Haque, V. M.
Ugaz, P. K. Thwar, Z. Chen, K. Alfano, M. B. Yim, M. Krishnan,
A. O. Fuller, R. G. Larson, D. T. Burke, M. A. Burns, Lab Chip
2005, 5, 1024 – 1032.
[8] C. I. Jönsson, S. Lundgren, S. J. Haswell, C. Moberg, Tetrahedron
2004, 60, 10515 – 10520.
[9] a) Review articles on directed evolution of enantioselective
enzymes: M. T. Reetz, Proc. Natl. Acad. Sci. USA 2004, 101,
5716 – 5722; M. T. Reetz in Advances in Catalysis, Vol. 49 (Eds.:
B. C. Gates, H. Knözinger), 2005, pp. 1 – 70; b) review on high-
throughput-screening systems for evaluation of enantioselective
catalysts and enzymes: M. T. Reetz, Angew. Chem. 2001, 113,
292 – 320; Angew. Chem. Int. Ed. 2001, 40, 284 – 310; c) reviews
on directed evolution: Directed Enzyme Evolution: Screening
and Selection Methods, Vol. 230 (Eds. F. H. Arnold, G. Geor-
giou), Humana Press, Totowa, NJ, 2003; d) Directed Molecular
Evolution of Proteins (or How to Improve Enzymes for
Biocatalysis) (Eds.: S. Brakmann, K. Johnsson), Wiley-VCH,
Received: November 25, 2005
Published online: January 27, 2006
Keywords: directed evolution · electrophoresis · enantiomer
.
separation · high-throughput screening · microreactors
Angew. Chem. Int. Ed. 2006, 45, 2463 –2466
ꢀ 2006 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim
2465