Study of the effect of laponite on Fricke XYLENOL ORANGE (cas 1611-35-4) gel dosimeter by optical techniques
-
Add time:07/20/2019 Source:sciencedirect.com
Optical absorbance and dynamic light scattering studies of Fricke XYLENOL ORANGE (cas 1611-35-4) gel dosimeters loaded with laponite were carried out with the aim to investigate possible effects of nanoparticles on the dosimetric properties and diffusion phenomena of ferric ions. A procedure for incorporating laponite nano-sized clay particles into the gel dosimeters, prepared using porcine gelatine as gelling agent, was successfully developed. The shape of the optical absorbance spectra of the gel dosimeters in the wavelength interval 350–750 nm have shown a slight dependence on the nanoparticles concentration and varied with the absorbed dose. All studied gel exhibited a linear dose response in the investigated interval 0–22 Gy. Neither the sensitivity to the radiation dose nor the diffusion coefficient were significantly altered by the addition of laponite into the Fricke xylenol orange gel formulation employed.
We also recommend Trading Suppliers and Manufacturers of XYLENOL ORANGE (cas 1611-35-4). Pls Click Website Link as below: cas 1611-35-4 suppliers
Prev:XYLENOL ORANGE (cas 1611-35-4)-based loop-mediated DNA isothermal amplification for sensitive naked-eye detection of Escherichia coli
Next:Colorimetric detection of scale drop disease virus in Asian sea bass using loop-mediated isothermal amplification with XYLENOL ORANGE (cas 1611-35-4)) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Reuse of sustainable materials for XYLENOL ORANGE (cas 1611-35-4) dye and copper (II) ion ammoniacal removal07/28/2019
- Bi-porous bioinspired chitosan foams with layered structure and their adsorption for XYLENOL ORANGE (cas 1611-35-4)07/27/2019
- Spectroscopic studies of interaction between XYLENOL ORANGE (cas 1611-35-4) and cationic surfactant in aqueous solution07/26/2019
- Study of optical absorbance and MR relaxation of Fricke XYLENOL ORANGE (cas 1611-35-4) gel dosimeters07/25/2019
- Fricke-gel dosimeter: overview of XYLENOL ORANGE (cas 1611-35-4) chemical behavior07/24/2019
- XYLENOL ORANGE (cas 1611-35-4) functionalised polymers to overcome diffusion in Fricke gel radiation dosimeters07/23/2019
- Colorimetric detection of scale drop disease virus in Asian sea bass using loop-mediated isothermal amplification with XYLENOL ORANGE (cas 1611-35-4)07/22/2019
- XYLENOL ORANGE (cas 1611-35-4)-based loop-mediated DNA isothermal amplification for sensitive naked-eye detection of Escherichia coli07/21/2019
- Does the gelation temperature or the sulfuric acid concentration influence the dosimetric properties of radiochromic PVA-GTA XYLENOL ORANGE (cas 1611-35-4) Fricke gels?07/19/2019
-
Health and Chemical more >