XYLENOL ORANGE (cas 1611-35-4) functionalised polymers to overcome diffusion in Fricke gel radiation dosimeters
-
Add time:07/23/2019 Source:sciencedirect.com
Gel dosimeters have the potential to measure radiation dose in 3D, allowing for improved treatment planning in radiotherapy. Despite extensive research over the last three decades, gel dosimeters have yet to achieve widespread clinical acceptance. The major limitation is the spatial instability of dose information, caused by diffusion of the small molecule radiographic components within the gel matrix. To overcome the issue of diffusion we propose a new approach to designing Fricke gel dosimeters, where the radiographic component, XYLENOL ORANGE (cas 1611-35-4) (XO), is chemically conjugated to the polymer matrix prior to gel formulation. We introduce the synthesis of a novel alkyne-functionalised xylenol orange chelate and the chemical conjugation to azide modified poly(vinyl alcohol) through copper catalysed azide-alkyne click chemistry. Dosimeters composed of the novel PVA-bound XO, even with a low concentration of XO (0.1 mM), show good contrast between irradiated and non-irradiated voxels. Critically, they show no loss of dose information and limited blurring in optical CT imaging, even 18 h post-irradiation, as the diffusion of the Fe(III)-XO chelates is prevented.
We also recommend Trading Suppliers and Manufacturers of XYLENOL ORANGE (cas 1611-35-4). Pls Click Website Link as below: cas 1611-35-4 suppliers
Prev:Colorimetric detection of scale drop disease virus in Asian sea bass using loop-mediated isothermal amplification with XYLENOL ORANGE (cas 1611-35-4)
Next:Fricke-gel dosimeter: overview of XYLENOL ORANGE (cas 1611-35-4) chemical behavior) - 【Back】【Close 】【Print】【Add to favorite 】
- Related Information
- Reuse of sustainable materials for XYLENOL ORANGE (cas 1611-35-4) dye and copper (II) ion ammoniacal removal07/28/2019
- Bi-porous bioinspired chitosan foams with layered structure and their adsorption for XYLENOL ORANGE (cas 1611-35-4)07/27/2019
- Spectroscopic studies of interaction between XYLENOL ORANGE (cas 1611-35-4) and cationic surfactant in aqueous solution07/26/2019
- Study of optical absorbance and MR relaxation of Fricke XYLENOL ORANGE (cas 1611-35-4) gel dosimeters07/25/2019
- Fricke-gel dosimeter: overview of XYLENOL ORANGE (cas 1611-35-4) chemical behavior07/24/2019
- Colorimetric detection of scale drop disease virus in Asian sea bass using loop-mediated isothermal amplification with XYLENOL ORANGE (cas 1611-35-4)07/22/2019
- Study of the effect of laponite on Fricke XYLENOL ORANGE (cas 1611-35-4) gel dosimeter by optical techniques07/20/2019
- XYLENOL ORANGE (cas 1611-35-4)-based loop-mediated DNA isothermal amplification for sensitive naked-eye detection of Escherichia coli07/21/2019
- Does the gelation temperature or the sulfuric acid concentration influence the dosimetric properties of radiochromic PVA-GTA XYLENOL ORANGE (cas 1611-35-4) Fricke gels?07/19/2019
-
Health and Chemical more >


